Published on: November 22, 2016
Utilizing MgO and MgO/Au for the measurement of energy and intensity of X-ray; instruments and materials
Gholamreza Fardipour Raki1, Babak Jaleh2, Milad Daneshnazar3
1School of Particles and Accelerator, Institute for Research in Fundamental Sciences (IPM), P.O. Box 19395-5531, Tehran, Iran.
Abstract:
Semiconductor materials characterized by wide-bandgaps are well-suitable for measuring and detecting high-energy particles, such as x rays. According to the insulating properties of metal oxides and the sensing capabilities of two-dimensional nanomaterials, magnesium oxide (MgO) becomes a promising sensing material. To change the sensing behavior of composites, metal nanoparticles used to capitalize on their synergistic effects and change in reactions. According to this, magnesium oxide/gold (MgO/Au) nanocomposite was synthesized using facile and straightforward methods, namely laser ablation in liquid and magnetic stirring. In the study of electric response to x ray, it was observed that, compared to the energy change in photons, the MgO/Au nanocomposite shows higher sensitivity to intensity changes in x radiation. In contrast, MgO nanosheets demonstrate sensitivity to energy and intensity changes in radiation. With precise ammeter and appropriate analysis, these materials, when placed in the same device, have the potential to measure the energy and intensity of x rays. It is well established that semiconductors such as MgO with wide-energy-bandgaps exceeding 5 eV can demonstrate resistances in the megaohm range in prepared samples for analysis. Due to this elevated resistance, the electric current flowing through the biased material typically falls within the hundreds of picoamperes (pA). Such low current levels pose significant challenges for measurement using standard and even advanced ammeters, as they are highly susceptible to interference from noise sources. To mitigate this challenge, we have developed and evaluated a circuit designed to supply the necessary bias voltage and accurately measure extremely low electrical currents, specifically at the 10 pA level.
More Related Videos
07:55Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering
Published on: April 17, 2018
06:49In situ Grazing Incidence Small Angle X-ray Scattering on Roll-To-Roll Coating of Organic Solar Cells with Laboratory X-ray Instrumentation
Published on: March 2, 2021
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Electronic Distance Measuring Instruments
Free Energy
What is Energy?
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...