Related Experiment Video
Updated: Feb 12, 2026

A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
Published on: May 11, 2020
Acetabular component placement accuracy and short-term outcomes in total hip arthroplasty : comparison of robotic
Tatsuroh Suzuki1, Norio Yamamoto2,3, Takanori Miura3,4
1Department of Orthopaedic Surgery, Oyumino Central Hospital, Chiba, Japan.
Aims:
Precise acetabular component positioning is critical to the success of total hip arthroplasty (THA). Mako uses CT-based robotic assistance, whereas AR-hip is an augmented reality-based portable navigation system operating without preoperative CT and at lower costs. Although both systems improve accuracy, direct comparative data are scarce. We compared cup placement accuracy and short-term outcomes between Mako robotic arm and AR navigation systems.
Methods:
This single-centre retrospective cohort study included 192 primary THAs (Mako, 147; AR navigation, 45). Cup placement accuracy was assessed three-dimensionally using postoperative CT, evaluating cup alignment (radiological inclination (RI) and anteversion (RA)) and position (centre of rotation (COR)). Short-term outcomes were evaluated using the Harris Hip Score (HHS), Japanese Orthopaedic Association hip score (JOA), Japanese Hip-disease Evaluation Questionnaire (JHEQ), Timed Up and Go (TUG), and 10 m walk test (10MWT). Baseline differences were adjusted using propensity score overlap weighting.
Results:
Mako demonstrated significantly superior accuracy than AR navigation, with smaller absolute errors in cup angles (RI 2.0° vs 3.0°, p = 0.045; RA 1.7° vs 2.4°, p = 0.005) and COR errors in the superior-inferior direction (1.5 mm vs 3.7 mm, p < 0.001). More cases were within 5° of planned angles with Mako (92.3% vs 77.7%, p = 0.030), while Lewinnek safe zone rates were high in both groups (99.5% vs 95.2%, p = 0.202). Short-term clinical scores and functional recovery at discharge were similar between groups. Operating time and blood loss were greater with Mako (122.6 vs 103.5 mins; 242.5 vs 171.5 ml; both p < 0.001). Subgroup analyses showed greater advantages of Mako in complex cases, such as obesity and developmental dysplasia of the hip, although interactions were insignificant.
Conclusion:
Mako demonstrated superior cup placement accuracy and COR reconstruction compared with AR navigation, with comparable short-term clinical outcomes, potentially offering advantages in complex cases. However, further research is warranted to clarify its long-term outcomes and cost-effectiveness.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
Accuracy and Precision

