Related Experiment Video
Updated: Feb 12, 2026

Wind Tunnel Experiments to Study Chaparral Crown Fires
Published on: November 14, 2017
Comparison of Marginal Adaptation in Lithium Disilicate Crowns Using Three Fabrication Techniques: An In Vitro Study
Asmita Sodhi1, Pradeep Bansal2
1Department of Prosthodontics, Sodhi Dental Clinic and Implant Centre, Faridkot, IND.
Abstract:
Introduction The durability of all-ceramic crowns in clinical settings is fundamentally influenced by the precision of their margins, as significant marginal discrepancies can lead to the dissolution of cement, microleakage, the development of secondary caries, and periodontal issues. This research sought to evaluate the vertical marginal precision of lithium disilicate crowns fabricated via the traditional heat-press methodology, the computer-aided design-milled wax pattern subsequently subjected to heat-pressing, and the fully digital computer-aided design/computer-aided manufacturing (CAD/CAM) milling of lithium disilicate materials. Materials and methods Thirty lithium disilicate crowns were fabricated on an identical master die of a prepared maxillary left second premolar and equally divided into three groups (n = 10): Group 1, conventional heat press using manually waxed patterns (control); Group 2, heat-press using CAD-milled wax patterns; and Group 3, fully digital CAD/CAM milling of lithium disilicate blocks (IPS e.max CAD LT A2, Ivoclar Vivadent, Schaan, Liechtenstein) followed by crystallization firing. All procedures were performed by a single operator. Vertical marginal gaps were measured at four indexed points using a stereomicroscope at 20x magnification (Leica M205 C; Leica Microsystems GmbH, Wetzlar, Germany). Data were then analyzed (α = 0.05). Results Significant intergroup differences were observed (p = 0.0001). Group 3 (fully digital) exhibited the smallest mean marginal gap, followed by Groups 2 and 1. Post-hoc analysis confirmed significant differences between all pairs on the mesial, distal, and palatal surfaces (p < 0.05). On the labial surface, Group 3 remained superior to Group 2 (p = 0.0021); however, no significant difference was noted between Groups 1 and 3 (p = 0.8739). Conclusion Fully digital CAD/CAM milling of lithium disilicate provided superior vertical marginal accuracy compared to heat-pressed techniques. Incorporating CAD-milled wax patterns significantly improved the fit compared to conventional manual waxing.
Related Concept Videos
Crown Ethers
Margin of Error
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...

