Related Experiment Video
Updated: Feb 13, 2026

Osmotic Drug Delivery to Ischemic Hindlimbs and Perfusion of Vasculature with Microfil for Micro-Computed Tomography Imaging
Published on: June 29, 2013
Development and Validation of a Harmonization Pipeline for Multi-Site Computed Tomography Perfusion Cerebral Blood
Pattarawut Charatpangoon1,2, Jianhai Zhang1,2, Nishita Singh3
1Departments of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, Canada.
Background:
Computed tomography perfusion (CTP)-derived cerebral blood flow (CBF) maps are widely used to study infarct volume and growth. Multi-site CTPs often have site biases that can alter thresholds and increase errors. However, the clinical impact of inter-site variability on infarct quantification is unclear. We examined this variability and developed an automated harmonization pipeline for multi-site CTP datasets to mitigate infarct assessment errors.
Methods:
We analyzed 741 CTP cases from the Alteplase compared to Tenecteplase trial across eight sites. CBFs were registered and segmented into grey-matter/white-matter (GM/WM). We scaled mean GM/WM CBFs into physiological ranges and applied ComBat, an empirical Bayesian method, to reduce inter-site bias. We assessed clinical utility by comparing infarct-core volumes from original versus harmonized maps with a relative-CBF-based reference, and comparing large-core infarct identification using CBF-based volume thresholds.
Results:
The original mean CBF deviated from physiological range with high variance and significant inter-site differences. After applying the scaling factor, the mean CBF (GM/WM) shifted to physiological ranges (49.3 ± 6.0/23.5 ± 2.5 ml/100g/min), and ComBat effectively eliminated inter-site differences. In 199 cases with complete reference data for clinical evaluation, harmonization decreased mean absolute error for infarct volume by 39% (12.7 to 7.7 ml), improved agreement (bias -7.9 to -5.8 ml; narrower 95%CI), and increased accuracy of large-core classification at a 60 ml-threshold by 5.0% (net reclassification improvement:0.310, 95%CI:0.036-0.603).
Conclusion:
Our harmonization pipeline rescaled multi-site CBF maps to physiological range, reducing inter-site variability and errors in infarct core estimation and large-core classification. Multi-site harmonization should become standard in CTP datasets to avoid erroneous conclusions about infarct size and growth.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Blood Flow
Harmonic Mean
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
Development of Blood Vessels
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....

