Altitude-Dependent Differences in Non-Volatile Metabolites of Tea Leaves Revealed by Widely Targeted Metabolomics

Jilai Cui1,2,3, Yiwei Yang1,2, Yu Che1,2

  • 1Dabie Mountain Laboratory, College of Tea and Food Science, Xinyang Normal University, Xinyang 464000, China.

Biology
|February 12, 2026
PubMed
Abstract

Related Concept Videos

Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
6.2K
Leaving Groups02:14

Leaving Groups

The nature of leaving groups strongly influences the outcome of a nucleophilic substitution reaction.
In general, in a nucleophilic substitution reaction, a nucleophile displaces a functional group, called the leaving group, from the substrate to give a substituted product. A leaving group departs the substrate molecule through heterolytic cleavage, taking the pair of electrons with it to become a relatively stable weak base in the form of an anion or a neutral molecule.  
In a...
9.8K
Electric Potential and Potential Difference01:16

Electric Potential and Potential Difference

Suppose a positive test charge moves away from a positive static charge, then the Coulomb force does positive work, and its electric potential energy decreases. The potential energy per unit charge is defined as the electric potential. The electric potential is independent of the test charge.
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
5.8K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.4K
Identifying Statistically Significant Differences: The F-Test01:14

Identifying Statistically Significant Differences: The F-Test

The F-test is used to compare two sample variances to each other or compare the sample variance to the population variance. It is used to decide whether an indeterminate error can explain the difference in their values. The underlying assumptions that allow the use of the F-test include the data set or sets are normally distributed, and the data sets are independent of each other. The test statistic F is calculated by dividing one variance by another. In other words, the square of one standard...
3.9K
Sum and Difference OpAmps01:22

Sum and Difference OpAmps

Operational amplifiers (op-amps) are versatile devices that extend beyond amplification. In this context, two specific op-amp configurations are explored: the summing and difference amplifiers.
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...
1.4K