Related Experiment Video
Updated: Feb 14, 2026

Murine Model of Leukemia Relapse to Induction Chemotherapy for Acute Lymphoblastic Leukemia
Published on: October 17, 2025
Ibrutinib with Venetoclax in Patients with Relapsed/Refractory Chronic Lymphocytic Leukemia: A Phase II Study
Mahesh Swaminathan1, Alessandra Ferrajoli1, Philip A Thompson2
1Department of Leukemia, The University of Texas MD Anderson Cancer Center, Houston, Texas.
Abstract:
We explored the efficacy of the combination of ibrutinib + venetoclax in patients with relapsed and/or refractory (R/R) chronic lymphocytic leukemia (CLL). This phase II study enrolled 80 patients between July 2016 and September 2018. Patients received ibrutinib for the first 3 cycles, followed by ibrutinib + venetoclax for 24 cycles. Of the 79 treated patients, the median age was 61 years (IQR, 56-69); 65 (65/76, 86%) had unmutated IGHV and 29 (37%) had either del(17p) or a TP53 mutation. The median number of prior treatments was 1 (range, 1-3). The primary endpoint, best complete remission (CR) and CR with incomplete count recovery (CRi), was 67%, with a bone marrow undetectable measurable residual disease [10-4 sensitivity (U-MRD4)] rate of 61%. At 95.5 months of median follow-up, the estimated 7-year progression-free survival rate was 63.3%. Grade ≥3 neutropenia and thrombocytopenia occurred in 38% and 13% of patients, respectively. The 24-cycle ibrutinib + venetoclax combination led to high rates of CR/CRi and bone marrow U-MRD4 in patients with R/R CLL.
Significance:
The 24-cycle ibrutinib + venetoclax combination led to high rates of CR/CRi and bone marrow U-MRD4 in patients with R/R CLL. Responses were durable, including in patients with high-risk genomics.
More Related Videos
Related Concept Videos
Phase Diagrams
Phase Transitions
Bioavailability Study Design: Healthy Subjects Versus Patients
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Phase Changes
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...

