Related Experiment Video
Updated: Feb 14, 2026

Full-Endoscopic Isolation Zone Technique for the Treatment of Lumbar Disc Herniation
Published on: April 7, 2023
Endoscopic virtual ruler (EVR) based on image recognition technology: a novel tool for decision support in endoscopic
Yaxian Kuai1, Bin Sun1, Zhihong Wang1
1Key Laboratory of Digestive Diseases of Anhui Province, Department of Gastroenterology, The First Affiliated Hospital of Anhui Medical University, No.81 Jixi Road, Shushan District, Hefei City, 230031, Anhui Province, China.
Background And Aim:
Accurate preoperative assessment of lesion size is crucial for selecting the appropriate endoscopic resection technique. However, the current assessment of lesion size still mainly relies on visual estimation, lacking objective measurement methods. To develop and validate an Endoscopic Virtual Ruler (EVR) based on image detection technology for objective measurement of lesion size before endoscopic treatment.
Methods:
Using computer image recognition technology and laser spot imaging principle, EVR was formed to detect the size of lesions. In vitro animal and human experiments were carried out to verify the accuracy and safety of EVR by comparing its measurement results with the actual size and the visual inspection results of endoscopists.
Results:
In 30 in vitro tests, the measurement error of EVR was 0.08 ± 0.17 cm (95% CI 0.01-0.14), and the relative accuracy of the measurement was 92.80% ± 5.50%( 95% CI 90.75-94.85%). In 58 clinical lesions, the mean error for visual estimation was 0.16 ± 0.66 cm (95% CI- 0.01 to 0.33), while EVR showed 0.12 ± 0.32 cm (95% CI 0.04-0.21). EVR was significantly more accurate (85.68% ± 15.25%) than visual estimation (67.08% ± 22.59%, p < 0.001). EVR was more effective [48 (82.8%) vs 31 (46.6%), p = 0.001]. In the multivariable model, EVR-assisted measurement was independently associated with achieving clinically acceptable accuracy (OR 4.38, 95% CI 1.84-10.43, p = 0.001). EVR also demonstrated higher consistency in lesion size classification (Kappa = 0.764 vs. 0.522, p < 0.001). For lesions < 1 cm, EVR misclassified only 12.5% as 1-2 cm, significantly less than the 50% misclassification rate with visual estimation (p = 0.034). There was no laser damage side effect.
Conclusion:
EVR offers an accurate, safe, and objective measurement tool, which is helpful for the formulation of appropriate treatment decisions.
Chinese Clinical Trial Registry:
ChiCTR2400085998.
Related Concept Videos
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):

