Related Experiment Video
Updated: Feb 14, 2026

Author Spotlight: Unveiling Mitochondrial Contact Sites and Architectural Insights
Published on: June 16, 2023
Research and Implementation of an Improved Non-Contact Online Voltage Monitoring Method
Meiying Liao1,2,3, Jianping Xu1,3, Wei Ni4
1School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China.
Abstract:
High-precision non-contact online voltage monitoring has attracted considerable attention due to its improved safety. Based upon existing research works and validation of non-contact voltage measurement techniques, an enhanced approach for online voltage monitoring is proposed in this paper. By analyzing the influence of the relationship between coupling capacitance and input capacitance on monitoring results, an RC-type signal input circuit with enhanced adaptability has been designed for practical engineering scenarios that may involve large input capacitance. Furthermore, a mixed-signal measurement method based on phase dithering is proposed to eliminate detection errors caused by relative phase drift during synchronous sampling in existing signal injection approaches. This improvement enhances measurement accuracy and offers a more robust theoretical basis for selecting injection signal frequencies. The hardware circuit architecture and data processing scheme presented in this work are straightforward and have been validated using an experimental prototype tested at 50 Hz/500 V and 2000 Hz/300 V. Long-term energized testing demonstrates that the system operates stably at room temperature with a relative measurement error below 0.5%. This study provides a high-precision, easily implementable non-contact measurement solution for online monitoring of low-frequency, low-voltage signals in complex electromagnetic environments such as industrial control signals, low-voltage power signals, and rail transit signals.
Related Concept Videos
Voltage
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Voltage Dividers
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the current...