Recognition of Output-Side Series Arc Fault in Frequency Converter-Controlled Three-Phase Motor Circuit
Aixia Tang1,2, Zhiyong Wang2, Hongxin Gao2
1College of Mining, Liaoning Technical University, Fuxin 123000, China.
None:
Timely identification of series arc faults (SAFs) is of vital importance for preventing electrical fires. How to identify SAFs at the output side of a frequency converter (i.e., output-side SAF) is still not clear. A new approach of identifying output-side SAFs by analyzing the output current signals from frequency converters was proposed. First, output-side SAF experiments were performed with harmonic power supplies. Second, the output current signals were decomposed into eight modal components by empirical wavelet transform and an autoregressive model was established. The autoregressive model parameters and the energy ratios of the first three modal components were adopted as the fault features. Finally, an optimized support vector machine was designed and employed to identify SAFs. Comparison tests with similar methods were performed and performance tests under different noise levels and operation conditions were conducted. The test results indicated that the proposed scheme can effectively recognize output-side SAFs. Its runtime is shorter than 1.4 ms. This method provides a reference for the development of industrial three-phase SAF detection devices.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
07:43A Simple Approach to Perform TEER Measurements Using a Self-Made Volt-Amperemeter with Programmable Output Frequency
Published on: October 5, 2019
Related Concept Videos
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
RLC Series Circuits
Three-Phase Circuits
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...