Recognition of Output-Side Series Arc Fault in Frequency Converter-Controlled Three-Phase Motor Circuit

Aixia Tang1,2, Zhiyong Wang2, Hongxin Gao2

  • 1College of Mining, Liaoning Technical University, Fuxin 123000, China.

PubMed
Abstract

Related Concept Videos

Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
431
RLC Series Circuits01:30

RLC Series Circuits

An RLC series circuit comprises an inductor, a resistor, and a charged capacitor connected in series. When the circuit is closed, the capacitor begins to discharge through the resistor and inductor by transferring energy from the electric field to the magnetic field. Here, the resistor connected to the circuit causes energy losses; therefore, on the complete discharge of the capacitor, the magnetic field energy acquired by the inductor is less than the original electric field energy of the...
3.8K
Three-Phase Circuits01:22

Three-Phase Circuits

AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
869
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
479
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
423
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
453