Related Experiment Video
Updated: Feb 14, 2026

Monitoring of Systemic and Hepatic Hemodynamic Parameters in Mice
Published on: October 4, 2014
Online Multi-Parameter Identification for PMSM Parameter Monitoring Based on a ZOH Model and Dual-Sampling Strategy
Sidong He1, Xuewei Xiang1, Hui Li1
1State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.
Abstract:
The accuracy of online parameter identification for permanent magnet synchronous motors (PMSMs) is constrained by discrete model errors, rank deficiency in the steady-state identification matrix, and voltage deviations resulting from inverter nonlinearities. This paper proposes a multi-parameter identification method acting as a high-precision virtual sensor, based on Zero-Order Hold (ZOH) discretization and an inverter nonlinear voltage compensation scheme utilizing a dual-sampling strategy. First, a discrete model of the PMSM, accounting for rotor position variations within the control period, is established using the ZOH discretization method. Compared with the forward Euler discretization method, this approach effectively minimizes discretization model errors, especially under high-speed operating conditions where rotor position variations are significant. Second, the rank deficiency problem of the steady-state identification matrix is overcome by combining d-axis small-signal injection with a dual-sampling strategy. Furthermore, the Forgetting Factor Recursive Least Squares (FFRLS) algorithm is introduced to achieve online multi-parameter identification. Finally, the influence mechanisms of the dead-time effect, power switch voltage drop, and turn-on delay on the output voltage are analyzed. Consequently, an inverter nonlinear voltage compensation strategy tailored for the dual-sampling mode is proposed. Experimental results demonstrate that the proposed method significantly enhances parameter identification accuracy across the entire speed range. Specifically, under high-speed conditions, the identification errors for resistance, inductance, and flux linkage are maintained within 5.47%, 4.05%, and 2.46%, respectively.
Related Concept Videos
Wave Parameters
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Distributions to Estimate Population Parameter
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Dosage Regimens: Partial Pharmacokinetic Parameters
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...