Related Experiment Video
Updated: Feb 14, 2026

Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
Published on: October 20, 2010
Indocyanine Green (ICG) Fluorescence vs. Tc-99m Lymphoscintigraphy: Optimizing Sentinel Lymph Node Detection in
Matteo Matteucci1, Antonio Pesce2, Bruno Cirillo3
1Department of Medicine and General Surgery, University of Milan, 20122 Milan, Italy.
None:
Background: Sentinel lymph node (SLN) biopsy has emerged as a cornerstone in melanoma staging, offering targeted evaluation of regional lymphatic spread and guiding therapeutic decision-making. Traditionally, SLN mapping relies on lymphoscintigraphy using technetium-99m (Tc-99m) radiocolloid, but in recent years, indocyanine green (ICG) fluorescence imaging has emerged as a promising alternative. The aim of this review is to evaluate the diagnostic accuracy of ICG-near-infrared (NIR) imaging compared to standard Tc-99m lymphoscintigraphy in SLN biopsy (SLNB). Methods: A systematic review and meta-analysis were conducted, including 12 studies. The primary outcome was the false-negative rate; secondary outcomes included the total number of sentinel lymph nodes (SLNs) identified by ICG-NIR imaging and Tc-99m lymphoscintigraphy, the number of metastatic SLNs detected by each method, and the number of patients with metastatic disease. The statistical analysis for dichotomous variables was performed using the "Odds Ratio" (O.R.) calculated with the Mantel-Haenszel method. For continuous variables, the analysis utilized the "Mean Difference" calculated by the inverse variance method. All data are presented with a 95% confidence interval (CI). Results: ICG was associated with a significantly higher number of SLNs identified compared to Tc-99m (O.R.: 0.41, 95% CI: 0.34-0.49; p < 0.00001), while no significant differences were found in the detection of metastatic nodes, either as a proportion of total SLNs (O.R.: 1.04, 95% CI: 0.86-1.25; p = 0.68) or relative to total positive nodes (O.R.: 0.36, 95% CI: 0.16-0.81; p = 0.01). No statistically significant differences between the two techniques were found in the detection of metastatic patients (OR: 0.80, 95% CI: 0.31-2.03, p = 0.33) and in the total number of false-negative patients missed (risk difference (RD): 0.03, 95% CI: -0.04 to 0.09, p = 0.93). Conclusions: While ICG identifies a higher number of SLNs compared to Tc-99m, its ability to detect metastatic involvement is comparable between the two modalities. No significant differences were observed in the proportion of metastatic SLNs, the total number of positive nodes detected, the number of metastatic patients identified, and the false-negative rate. Given its favorable profile, ICG could represent a reliable alternative or adjunct to Tc-99 in SLNB. However, prospective studies are warranted to validate its standalone diagnostic role.
Related Concept Videos
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Green Algae
Random and Systematic Errors

