Related Experiment Video
Updated: Feb 14, 2026

Author Spotlight: A New and Efficient Method for Comprehensive Metabolite Cytotoxicity Assessment of Triazole Pesticides in Plants
Published on: December 22, 2023
A Chemiluminescent Magnetic Enzyme Immunoassay Method for 2 Triazole Pesticide Detection in Wheat
Xin Shi1,2, Kai Huang1, Baoyuan Guo1,2,3
1School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Abstract:
We developed an alkaline phosphatase (AP) chemiluminescence immunoassay method by combining the superparamagnetic magnetic beads and the biotin-streptavidin signal amplification system to detect the triazolone and tebuconazole in wheat. Through optimization of the extraction solution and extraction time, acetonitrile-PBS was selected as the extraction solution with an extraction time of 5 min as the optimal pretreatment condition. Optimizing the dilution ratio of antigen antibodies, the optimal detection conditions were selected as the dilution ratios of 1:8000 and 1:20,000 for the triazolone monoclonal antibody solution and biotinylated triazolone solution, and 1:4000 and 1:20,000 for the tebuconazole monoclonal antibody solution and biotinylated tebuconazole solution, respectively. Under the optimal conditions, the method demonstrated that the limits of detection (LOD) of triazolone and tebuconazole were 0.002835 μg·mL-1 and 0.00064 μg·mL-1, respectively. The recovery rate was between 90.1% and 103.6%, and the relative standard deviation (RSD) was lower than 10%. The cross-reaction rates for structural analogs were all less than 0.1%, showing good specificity. In actual sample detection, this method did not detect triazolone and tebuconazole, and the results were consistent with UHPLC-MS/MS.
Related Concept Videos
Enzymes
Enzyme deficiencies can often translate into life-threatening diseases. For example, a genetic abnormality resulting in the deficiency of the enzyme G6PD...
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Enzyme-linked Receptors
Neurotrophin (NT) receptors are a family of RTKs, including trkA, trkB, and trkC (tropomyosin-related kinase) receptors. TrkA is specific for nerve growth factor (NGF), neurotrophin-6, and neurotrophin-7. TrkB binds...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Enzyme Inhibition