Related Experiment Video
Updated: Feb 15, 2026

Percutaneous Contrast Echocardiography-guided Intramyocardial Injection and Cell Delivery in a Large Preclinical Model
Published on: January 21, 2018
A multi-level segmentation-guided diffusion model for streak artifact reduction in routine non-contrast chest CT
Jingxin Liu1,2, Xinran Zhu3,4, Zhangzhen Shi5
1Department of Radiology, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China. jingxin@jlu.edu.cn.
None:
Streak artifacts in non-contrast computed tomography (NCCT) can obscure anatomical details and even confuse radiologic signs. Existing methods for artifact reduction have limitations: specialized training data and high annotation costs hinder the performance scalability, inadequate anatomical constraints struggle to preserve fine details, and limited generative stability along with suboptimal artifact reduction compromises diagnostic applicability. Leveraging 96,641 CT slices (763 series) from four different CT scanners (100-140 kilovolt peak (kVp), 55-167 tube current-time product (mAs), 0.5-10 mm thickness), we proposed a novel guided diffusion method using multi-level anatomical segmentations to optimize streak artifact reduction in chest NCCT scans. During training, the model integrates artifact-free CT slices with segmentation maps and anatomical regions of interest (ROIs) via channel-wise concatenation at each diffusion step. During inference, artifact-affected samples are fed into the trained model to generate artifact-free outputs with structural integrity. Statistical analysis revealed a significant (p < 0.05) difference in Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) when comparing 47,032 artifact-affected samples to 49,609 artifact-free counterparts. Quantitative assessments demonstrated high consistency between generated outputs and reference standard artifact-free samples, with lung field SNR values of (26.67, standard deviation (SD) 2.01) vs. (26.11, SD 1.89) and lung-trachea CNR of (3.76, SD 0.77) vs. (3.78, SD 0.56) (both p > 0.05). Compared to four novel studies, our method achieved superior overall Peak Signal-to-Noise Ratio (PSNR) (36.952, SD 0.671), Structural Similarity Index (SSIM) (0.863, SD 0.013), and Dice Similarity Coefficient (DSC) (0.959, SD 0.031), with all p < 0.05. Moreover, ablation studies indicated that an appropriate segmentation guidance (Level-2) optimally balances anatomical structure constraints and artifact reduction efficiency, demonstrating superior performance in distinct organ or tissue regions compared to coarser and finer-grained guidance strategies. The proposed method has the potential to improve clinical analysis for chest NCCT by optimizing streak artifact reduction while enhancing medical image quality.
More Related Videos
Related Concept Videos
Diffusion
Diffusion
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
Oxidation-Reduction Reactions

