Related Experiment Video
Updated: Feb 16, 2026

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Patient exposure in paediatric Interventional Cardiology: a multicenter inter-comparison of clinical practices in
Francesca De Monte1, Angelo Giannone2, Andrea Bettinelli1
1Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy.
Purpose:
This multicenter study aims to assess compliance with Image Gently Alliance dose optimization principles in paediatric Interventional Cardiology (IC) and to examine inter-center variability in patient radiation exposure.
Material And Methods:
Leading centers in Italy were involved. An operational survey,developed in agreement with the Image Gently recommendations, was administered to investigate clinical practices and identify any deviations from established guidelines.Data from 2841 procedures were collected. Dosimetric data (PKA, Ka,r, fluoroscopy time) from centers were compared and analyzed alongside the questionnaire responses.Inter-center differences were assessed using the Kruskal-Wallis test (p < 0.05).
Results:
Despite adherence to recommendations,the questionnaire identified deviations correlated with exposure,including failure to remove the anti-scatter grid for patients < 20 kg, excessive magnification,and extensive cine-acquisition. Statistically significant inter-center differences in dose were observed. Centre A shows a significant reduction in patient dose for almost all procedure types. As an example, for angioplasty, centre A showed a lower median value (PKA = 3.5 Gy·cm2), less than half that of C (PKA = 9.2 Gy·cm2), D (PKA = 10.3 Gy·cm2) and E (PKA = 10.0 Gy·cm2). Centre E exhibited higher doses for most procedures: a median PKA = 5.6 Gy·cm2 in diagnostic catheterizations compared to a range of 1.6-4.6 Gy·cm2 in the other centres, and a median PKA = 3.2 Gy·cm2 for Patent Ductus Arteriosus closure compared to 0.7-1.4 Gy·cm2. These results can be attributed to an outdated equipment.
Conclusions:
Investigating clinical practices in a multicenter context is crucial for harmonizing operations and ensuring dose monitoring. Identifying differences in practices, equipment, and image quality that affect patient dose is essential for enhancing patient safety.
More Related Videos
Related Concept Videos
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Nursing Interventions II: Selecting and Classifying the Nursing Interventions
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Community Based Intervention
Foundations of Community Mental Health Programs
Central to the success of community-based interventions is the...
Operant Conditioning Intervention
In operant conditioning, behaviors that are...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...