Related Experiment Video
Updated: Feb 18, 2026

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Targeting and monitoring mean arterial pressure in critical illness: A mixed-methods service evaluation
Isla MacKay1, Ian Piper2, Annemarie B Docherty2
1Edinburgh Medical School, University of Edinburgh, U.
Background:
In sepsis and cardiac arrest, arterial hypotension is associated with poorer outcomes, including renal injury and mortality. Guidelines recommend a mean arterial pressure (MAP) target of ⩾65 mmHg, but supporting evidence is limited. We undertook a service evaluation which aimed to: (1) assess clinical opinion regarding the optimal MAP target in intensive care (ICU); and (2) evaluate MAP target adherence at the Royal Infirmary Edinburgh ICU, quantifying levels of hypotension.
Methods:
We utilised a concurrent triangulation mixed-methods approach, integrating semi-structured consultant interviews and quantitative analysis of patient-level blood pressure data. Blood pressure data were collected at 1-min intervals for the first 72 h of arterial monitoring. We defined hypotensive insults by five sequential minutes below MAP target.
Results:
We interviewed 18 consultants. Twelve (67%) reported a standard target of 65 mmHg. The importance of evidence-based, individualised, and flexible targets was emphasised. We included 208,570 min of monitoring time across 66 patients. At admission, 53 (80%) patients received a target of 65 mmHg. Mean (SD) MAP was lower in patients on vasopressors than those not on vasopressors (77.6 (14.2) vs 86.9 (17.3) mmHg, p = 0.0001). Hypotension affected 55 (83%) patients and accounted for >10% of monitoring time in thirteen (20%). Median pressure-time index (PTI) was 3.4 mmHg * h; 24 (36%) patients had a PTI >10 mmHg * h.
Conclusions:
The optimal MAP target varied by patient, yet target personalisation remained limited in practice. Target adherence varied, with observed MAP both exceeding and undershooting set targets. Future research will explore the feasibility and implications of achieving tighter blood pressure control.
More Related Videos
06:18A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Measurement of Blood Pressure