Related Experiment Video
Updated: Aug 11, 2026

Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
Published on: December 27, 2012
Thickness-insensitive coding metasurface for broadband underwater acoustic radar cross section reduction
Jia-Wang Zhang1, Sheng-Dong Zhao2, Hao-Wen Dong3
1School of Mathematics and Statistics, Qingdao University, Qingdao 266071, People's Republic of China.
Abstract:
In underwater acoustics, reducing target detectability typically requires tailoring material thickness to specific frequencies, posing a fundamental constraint for broadband stealth. Here, we break this thickness-frequency dependency by introducing a 1-bit coding metasurface (CM) that achieves effective acoustic scattering suppression from 10 to 35 kHz with minimal sensitivity to cavity geometry. The CM comprises two deep-subwavelength units exhibiting a 180° reflection-phase difference: a metal-backed "0" unit that mimics a rigid boundary, and a "1" unit that encapsulates a stabilized air bubble with a polymer membrane to approximate a pressure-release surface. Through optimized spatial coding, the CM redirects incident plane waves into diffuse scattering patterns, substantially attenuating specular reflection. Both simulations and experiments confirm greater than 10 dB radar-cross section reduction over a broad angular span (up to 45°). Crucially, the reflection phase remains stable against variations in air-cavity thickness across the operational band, demonstrating a thickness-decoupled design paradigm. This work provides a robust, fabrication-friendly strategy for broadband underwater acoustic signature control, with potential applications in sonar camouflage and wavefront manipulation.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Parallel Resonance
Design Example
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
Electronic Distance Measuring Instruments

