Related Experiment Video
Updated: Feb 19, 2026

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Analysis on the thermal performance and economic efficiency of XLPE submarine cable based on
Minquan Ye1, Yue Zhang2, Huiying Wu2
1State Grid Fujian Economic Research Institute, Fuzhou, 350013, China. hdymq2014@163.com.
Abstract:
The operating temperature of a submarine cable must be lower than its permissible limit to prevent degradation of the insulation material. Ground conditions influence the heat transfer between the cable and the surrounding soil, thereby affecting both the cable temperature and its economic efficiency. This paper investigates the effect of ground conditions on the thermal performance and economic efficiency of a three-core 220 kV AC XLPE submarine cable. A coupled finite element model based on electromagnetic, thermal, and pore water flow fields is developed and the effects of laying depth, initial temperature, soil thermal conductivity, and permeability on the thermal performance and economic efficiency of the cable are investigated via parametric studies. The results show that the conductor temperature increases with increasing laying depth, and this effect becomes more pronounced at greater laying depths. The conductor temperature increases linearly with increasing initial temperature and decreases nonlinearly with increasing soil thermal conductivity. When the soil permeability is greater than 10-11 m2, the conductor temperature decreases as the soil permeability increases. From a thermal-economic perspective, the economic efficiency of submarine cables can be improved by laying cables in soil with high thermal conductivity or decreasing the laying depth. Laying cables in soil with higher permeability to improve cost-effectiveness is effective only when the soil permeability exceeds 10⁻11 m2.
Related Concept Videos
Cable Subjected to a Distributed Load
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...
Cable Subjected to Concentrated Loads
Cable: Problem Solving
Maximum Power Flow and Line Loadability