Related Experiment Video
Updated: Feb 20, 2026

Tumor Hypoxia Assessment: In Vivo 3D Oxygen Imaging Through Electron Paramagnetic Resonance
Published on: February 14, 2025
Development of a Novel Approach for In Vivo Tumor Hypoxia PET Imaging with Nitroreductase-Specific Responsive
Lumei Huang1,2, Shilan Peng1, Huanhuan Liu1
1Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, 4221-116 Xiang'an South Road, Xiamen 361102, China.
Abstract:
Tumor hypoxia is a major contributor to therapeutic resistance, including radio-, chemo-, and immunotherapy, and is closely linked to unfavorable clinical outcomes. PET imaging has shown promise in guiding the clinical treatment of hypoxic tumors. Here, we developed an NTR-responsive PET strategy for in vivo tumor hypoxia imaging using radiolabeled nitrogen mustard analogues (18F-NTRP and 18F-NCRP). Cell uptake studies with A549 cells showed that 18F-NTRP and 18F-NCRP exhibited approximately two fold higher uptake and good retention under hypoxic conditions. MicroPET imaging of A549 tumor-bearing mice revealed pronounced tumor accumulation of both 18F-NTRP and 18F-NCRP, with uptake values of 1.95 ± 0.37 and 2.86 ± 0.49 %ID/g, respectively, and a rapid clearance rate in normal organs. At 45 min postinjection, the tumor/muscle (T/M) ratios of 18F-NTRP and 18F-NCRP were 2.62 and 3.44, respectively, both substantially higher than that of 18F-FMISO (1.40, p < 0.05). Following dicoumarin-mediated inhibition of tumor NTR, the uptake and T/M ratio of 18F-NCRP were decreased to 1.25 ± 0.32 %ID/g and 1.26 (p < 0.001), respectively. Moreover, T/M ratios correlated well with HIF-1α (r2 = 0.71) and NTR (r2 = 0.66) levels in the A549 tumor. Collectively, PET imaging demonstrated that 18F-NCRP specifically targets tumor NTR and can potentially discriminate between varying degrees of hypoxia.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

