Related Experiment Video
Updated: May 4, 2026

Cardiac Catheterization in Mice to Measure the Pressure Volume Relationship: Investigating the Bowditch Effect
Published on: June 14, 2015
Agreement of thermodilution and direct Fick methods for cardiac output across varying haemodynamic conditions
Michael Melin1,2, Ida Haugen Löfman1,3, Dmitri Matan1,4
1Heart and Vascular and Neuro Theme, Division of Cardiology, Karolinska University Hospital, Stockholm, Sweden.
Introduction:
The direct Fick method is the gold standard for measuring cardiac output (Q). However, thermodilution (TD) is more widely used in clinical practice due to its feasibility. As the accuracy of TD-derived Q (QTD) may vary by flow state, it can influence the estimation of pulmonary vascular resistance (PVR) and pulmonary hypertension (PH) classification. This study aimed to compare QTD with Fick-derived Q (QF) across haemodynamic states and evaluate the clinical reliability of TD-derived PVR (PVRTD).
Methods:
We retrospectively analysed 852 right heart catheterizations (2014-22) with simultaneous QTD and QF measurements.
Results:
64% of patients had heart failure, and 20% had pulmonary arterial hypertension. QTD correlated strongly with QF (r = 0.78, P < .001) but demonstrated a flow-dependent bias-overestimating Q in low-flow states (+0.1 L/min) and underestimating it in normal/high flow (-0.48 L/min). Despite this, PVRTD accurately identified elevated PVRF at both 2 and 5 Wood unit thresholds (area under the curve = 0.97, P < .001). Agreement between QTD and QF was unaffected by tricuspid regurgitation severity.
Conclusion:
Although TD shows a predictable bias across flow states, it remains a clinically reliable method for estimating elevated PVR. These findings support the clinical utility of TD in PH assessment, while emphasizing the need for direct Fick measurement in low-output states-particularly in patients evaluated for advanced therapies such as transplantation.
More Related Videos
Related Concept Videos
Pathophysiology of Cardiac Performance
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...