Related Experiment Video
Updated: May 11, 2026

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Experimental comparisons of optical coherence tomography-based versus angiography-based time-averaged wall shear
Jarka Naser1, Nicholas A Fogell1, Miten Patel1
1Vascular Biology, National Heart and Lung Institute, Imperial College London, London, UK.
None:
An approach to rapid simulation of time-averaged wall shear stress (TAWSS) on 3D geometries created from 3D Quantitative Coronary Angiography (3D-QCA) methodology has been developed, which enables rapid computational fluid dynamic (CFD) shear stress simulation. We compared TAWSS estimated from 3D-QCA-CFD with optical coherence tomography (OCT)-based CFD simulations in coronary arteries. 15 normal and 5 stenotic coronary arteries in instrumented minipigs were studied. 3D arterial geometries were reconstructed from 3D-QCA and OCT using common centrelines and matched axial positions. Identical boundary conditions were used for both methods through directly measured vessel-specific inlet blood velocities. TAWSS was calculated for axially matched segments (n = 80 for normal arteries; n = 160 for stenotic arteries) and in 3 mm/60° sectors. Mean TAWSS simulation times for 3D-QCA and OCT-based CFD were 17.8 min and ~ 1.5 h respectively. There were significant but numerically small differences in TAWSS for normal arteries (-0.21 ± 0.64 Pa [95%CI -1.04,1.46], p < 0.001), and no significant difference for stenotic arteries (-0.39 ± 3.04 Pa [95%CI -6.35, 5.56], p = 0.25). Axial TAWSS profiles along vessel lengths were similar between the two methods. There is a trend of underestimation by 3D-QCA at higher values of TAWSS compared with OCT, due to differences in geometry dimensions. Similar spatial distributions of TAWSS in both normal and stenotic arteries were observed from co-registered TAWSS maps. This study suggests that 3D-QCA-based TAWSS is feasible in both normal and stenotic arteries and that further clinical evaluation of rapid TAWSS from 3D-QCA is warranted, which may facilitate clinical adoption of TAWSS assessment.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography