Related Experiment Video
Updated: Feb 25, 2026

Glycomics-Guided Glycoproteomics Facilitates Comprehensive Profiling of the Glycoproteome in Complex Tumor Microenvironments
Published on: February 7, 2025
Understanding m/z Range Settings for MS/MS Scans: A Case Study with Intact Glycopeptides
Tim S Veth1, Kathryn Kothlow1, Nicholas M Riley1
1Department Chemistry, University of Washington, Seattle, Washington 98195, United States.
Abstract:
Effective glycopeptide identification with tandem mass spectrometry (MS/MS) often relies on both low mass-to-charge (m/z) ions derived from glycan-specific oxonium ions and higher m/z peptide fragment ions that retain glycan modifications. Thus, glycoproteomic experiments benefit from a wider MS/MS scan range, i.e., the breadth of m/z values measured in fragmentation spectra, than those typically used in nonmodified peptide analyses. Here, we explore the implications of breaking a common axiom for scan range settings called the "5-10-15 rule" used to maximize transmission of ion populations of interest. This 5-10-15 rule, which defines the upper m/z value for a scan as a multiple of the first m/z value, comes from fundamental requirements for stable ion trajectories, where voltage settings must balance retention of low m/z ions while also generating effective pseudopotential wells to trap high m/z ions. Adhering to this calculation for MS/MS scan range settings can reduce glycopeptide ion coverage by excluding the analysis of either low m/z oxonium ions or high m/z fragment ions. We use a quadrupole-Orbitrap-linear ion trap Tribrid MS system (Orbitrap Ascend) to investigate the implications of following or breaking the 5-10-15 rule in MS/MS scans for glycopeptide characterization with higher-energy collisional dissociation (HCD), electron-transfer dissociation (ETD), and electron-transfer/higher-energy collision dissociation (EThcD). For scans with a first m/z value around m/z 120 (i.e., capturing most common glycan-specific oxonium ions), we show that breaking the 5-10-15 rule does not lead to a significant loss of fragment ion transmission at either extreme of the m/z range. We use this case study to discuss the concepts important to using the 5-10-15 rule wisely and when it can be practically ignored, such as using large scan ranges to improve glycopeptide characterization.
More Related Videos
08:51Profiling of Permethylated Mucin O-glycans Using Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry
Published on: June 20, 2025
08:37The Application of Open Searching-based Approaches for the Identification of Acinetobacter baumannii O-linked Glycopeptides
Published on: November 2, 2021
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry
Mass Spectrum