Related Experiment Video
Updated: Feb 26, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
AURA-CVC: Autonomous Ultrasound-guided Robotic Assistance for Central Venous Catheterization
Deepak Raina1,2, Lidia Al-Zogbi3,4, Brian Teixeira5
1Malone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD 21218, USA.
Purpose:
Central venous catheterization (CVC) is a critical medical procedure for vascular access, hemodynamic monitoring, and life-saving interventions. Its success remains challenging due to the need for continuous ultrasound-guided visualization of a target vessel and approaching needle, which is further complicated by anatomical variability and operator dependency. Errors in needle placement can lead to life-threatening complications. While robotic systems offer a potential solution, achieving full autonomy remains challenging. In this work, we propose an end-to-end robotic ultrasound-guided CVC pipeline, from scan initialization to needle insertion.
Methods:
We introduce a deep-learning model to identify clinically relevant anatomical landmarks from a depth image of the patient's neck, obtained using an RGB-D camera, to autonomously define the scanning region and paths. Then, a robot motion planning framework is proposed to scan, segment, reconstruct, and localize vessels (veins and arteries), followed by the identification of the optimal insertion zone. Finally, a needle guidance module plans the insertion under ultrasound guidance with operator's feedback. This pipeline was validated on a high-fidelity commercial phantom across 10 simulated clinical scenarios.
Results:
The proposed pipeline achieved 10 out of 10 successful needle placements on the first attempt. Vessels were reconstructed with a mean error of 2.15 mm, and autonomous needle insertion was performed with an error less than or close to 1 mm.
Conclusion:
To our knowledge, this is the first robotic CVC system demonstrated on a high-fidelity phantom with integrated planning, scanning, and insertion. Experimental results show its potential for clinical translation.
More Related Videos
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
Related Concept Videos
Cardiac Catheterization IV: Nursing Management
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Cardiac Catheterization II: Right Heart Catheterization