Related Experiment Video
Updated: Feb 27, 2026

Author Spotlight: Development of a Smartphone-Enhanced Paper-Based Device for Rapid Dengue NS1 Detection
Published on: January 26, 2024
In Silico Optimization of a Non-Invasive Optical Sensor for Hemoconcentration Monitoring in Dengue Fever Management
Murad Althobaiti1, Gameel Saleh1
1Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia.
Severe Dengue fever can cause Dengue Hemorrhagic Fever (DHF), a life-threatening condition characterized by plasma leakage and hemoconcentration. A hematocrit (Hct) rise of ≥20% is a key indicator for medical intervention, but current monitoring is invasive and intermittent. This study aims to determine the optimal design parameters for a non-invasive optical sensor to continuously monitor hemoconcentration. We developed a high-fidelity Monte Carlo model of light transport in a multi-layered skin model, with the epidermis set to a 5% melanin volume fraction (Fitzpatrick type II/III). To ensure signal reliability, simulations were conducted with a high photon count (1×108 photons), yielding a stochastic (Monte Carlo) signal-to-noise ratio of approximately 36 dB. We simulated diffuse reflectance at four characteristic wavelengths (577 nm, 660 nm, 800 nm-the isosbestic point-, and 940 nm) over source-detector separations of 0.5-8.0 mm. Sensor sensitivity was quantified as the reflectance change for a +25% relative Hct rise (e.g., 42% to 52.5%), mimicking severe hemoconcentration, and its dependence on baseline dermal blood volume fraction (BVF) was investigated. Sensor sensitivity showed a non-linear dependence on BVF, showing a direct correlation with perfusion level, reaching an optimal 6.41% for a robust 5% BVF at 8.0 mm. A dedicated sweep showed that even under low-perfusion shock conditions (1% BVF), the sensor maintains a highly significant sensitivity of 5.71% (also at 8.0 mm), indicating that sensitivity remains high across a physiologically relevant perfusion range. In the analysis, at a robust 5% BVF, the 800 nm wavelength demonstrated superior reliability, with peak sensitivity at 6.41% at 8.0 mm. Visible wavelengths (577 nm and 660 nm) exhibited high theoretical sensitivity, while 940 nm was compromised by water absorption. Based on these findings, a non-invasive optical sensor for hemoconcentration is most effective operating at 800 nm, within the evaluated spectral set, with a source-detector separation of ≥6.0 mm, targeting the deep dermis while minimizing superficial interference. This design provides an optimal balance of tissue penetration, robust sensitivity to Hct changes, and reduced sensitivity to oxygenation-related variability while maintaining signal stability. This work enables the design of a device for continuous monitoring, supporting continuous monitoring of hemoconcentration trends relevant to plasma leakage progression.
Severe Dengue fever can cause Dengue Hemorrhagic Fever (DHF), a life-threatening condition characterized by plasma leakage and hemoconcentration. A hematocrit (Hct) rise of ≥20% is a key indicator for medical intervention, but current monitoring is invasive and intermittent. This study aims to determine the optimal design parameters for a non-invasive optical sensor to continuously monitor hemoconcentration. We developed a high-fidelity Monte Carlo model of light transport in a multi-layered skin model, with the epidermis set to a 5% melanin volume fraction (Fitzpatrick type II/III). To ensure signal reliability, simulations were conducted with a high photon count (1×108 photons), yielding a stochastic (Monte Carlo) signal-to-noise ratio of approximately 36 dB. We simulated diffuse reflectance at four characteristic wavelengths (577 nm, 660 nm, 800 nm-the isosbestic point-, and 940 nm) over source-detector separations of 0.5-8.0 mm. Sensor sensitivity was quantified as the reflectance change for a +25% relative Hct rise (e.g., 42% to 52.5%), mimicking severe hemoconcentration, and its dependence on baseline dermal blood volume fraction (BVF) was investigated. Sensor sensitivity showed a non-linear dependence on BVF, showing a direct correlation with perfusion level, reaching an optimal 6.41% for a robust 5% BVF at 8.0 mm. A dedicated sweep showed that even under low-perfusion shock conditions (1% BVF), the sensor maintains a highly significant sensitivity of 5.71% (also at 8.0 mm), indicating that sensitivity remains high across a physiologically relevant perfusion range. In the analysis, at a robust 5% BVF, the 800 nm wavelength demonstrated superior reliability, with peak sensitivity at 6.41% at 8.0 mm. Visible wavelengths (577 nm and 660 nm) exhibited high theoretical sensitivity, while 940 nm was compromised by water absorption. Based on these findings, a non-invasive optical sensor for hemoconcentration is most effective operating at 800 nm, within the evaluated spectral set, with a source-detector separation of ≥6.0 mm, targeting the deep dermis while minimizing superficial interference. This design provides an optimal balance of tissue penetration, robust sensitivity to Hct changes, and reduced sensitivity to oxygenation-related variability while maintaining signal stability. This work enables the design of a device for continuous monitoring, supporting continuous monitoring of hemoconcentration trends relevant to plasma leakage progression.

