Related Experiment Video
Updated: May 2, 2026

Characterization of Anisotropic Leaky Mode Modulators for Holovideo
Published on: March 19, 2016
An Analysis of Diffracted Mode Outcoupling in the Context of Optical Gain Measurements of Organic Thin Films: A
Thilo Pudleiner1, Jan Hoinkis2, Christian Karnutsch1
1Research Group Integrated Optofluidics and Nanophotonics (IONAS), University of Applied Sciences Karlsruhe, 76133 Karlsruhe, Germany.
Abstract:
The sustained interest in efficient, low-cost, and straightforward-to-manufacture lasers has prompted intense research into organic semiconductor laser emitter materials in recent decades. The main focus of this research is determining the optical gains and losses of amplified spontaneous emission (ASE) in order to describe materials by their amplification signature. A method that has been used for decades as the standard technique for determining gain characteristics is the variable-stripe-length (VSL) method. The success of the VSL method has led to the development of further measurement techniques. These techniques provide a detailed insight into the nature of optical amplification. One such method is the scattered emission profile (SEP) method. In this study, we present an extension of the SEP method, the Diffracted Emission Profile (DEP) method. The DEP method is based on the detection of ASE by partial decoupling of waveguide modes diffracted by a one-dimensional grating integrated into a planar waveguide. Diffraction causes a proportion of the intensity to exit the waveguide, transferring the growth and decay process of the waveguide mode to the transverse mode profile of the diffracted mode. In the present article, an approach to determine the amplification signature of an organic copolymer is presented, utilizing partial decoupled radiation.
Related Concept Videos
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Interference
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Flame Photometry: Overview

