Thermal-Electrical Fusion for Real-Time Condition Monitoring of IGBT Modules in Transportation Systems

Man Cui1, Yun Liu2, Zhen Hu2

  • 1School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing 100081, China.

Micromachines
|February 27, 2026
PubMed
Summary

This study introduces a new method for monitoring Insulated Gate Bipolar Transistor (IGBT) health in transportation systems. It detects solder and bond wire failures using non-invasive thermal and electrical data for improved reliability.

Related Concept Videos

Induced Electric Fields: Applications01:27

Induced Electric Fields: Applications

An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
2.8K
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
548
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
594
Electrical Transport01:29

Electrical Transport

The electrical transport property of a material is defined by its resistance and conductivity. Resistance is the measure of a material's ability to resist the flow of electric current, while conductivity gauges its ability to allow the current to pass through, depending on the geometry of the measurement cell, such as electrode spacing and area. Conductivity is measured in Siemens (S). There are different types of conductance, including specific conductance, equivalent conductance, and molar...
25
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
594
Electrical Systems01:21

Electrical Systems

In electrical engineering, the analysis of networks composed of passive linear components — resistors (R), capacitors (C), and inductors (L) — is fundamental. These components are organized into circuits where the relationship between input and output can be analyzed using transfer functions. The transfer function of an RLC circuit, which relates the voltage across a capacitor to the input voltage, can be derived using Kirchhoff's laws.
To derive the transfer function, consider an RLC...
828