Quality-by-Design Compounding of Semisolids Using an Electronic Mortar and Pestle Device for Compounding Pharmacies:
Hudson Polonini1, Carolina Schettino Kegele1, Savvas Koulouridas1
1Fagron, Fascinatio Boulevard, 350, 3065 WB Rotterdam, The Netherlands.
Abstract:
Background/Objectives: Manual preparation of semisolid formulations (creams, ointments, gels) is prone to variability in mixing energy and time, which may compromise uniform API distribution. This study aimed to evaluate an Electronic Mortar and Pestle (EMP; Unguator™) as a standardized compounding tool, with objectives to: (i) validate stability-indicating UHPLC methods; (ii) assess content uniformity across jar strata; (iii) quantify the impact of mixing time and rotation speed via design of experiments (DOE); and (iv) verify cleaning effectiveness and cross-contamination risk. Methods: Five representative formulations were compounded: urea 40%, clobetasol 0.05%, diclofenac 2.5% in hyaluronic acid 3% gel, urea 10% + salicylic acid 1%, and hydroquinone 5%. UHPLC methods were validated per ICH Q2(R2) and stress-tested under acid, base, oxidative, thermal, and UV conditions. Homogeneity was assessed by stratified sampling (top/middle/bottom). A 32 factorial DOE (time: 2/6/10 min; speed: 600/1500/2400 rpm) modeled effects on % label claim and RSD. Cleaning validation employed hydroquinone as a tracer, with swab sampling pre-/post-use and post-sanitization analyzed by HPLC. Results: All UHPLC methods met specificity, linearity, precision, accuracy, and sensitivity criteria and were stability-indicating (Rs ≥ 1.5). Formulations achieved 90-110% label claim with strata CV ≤ 5%. DOE revealed speed as the dominant factor for clobetasol, urea, and diclofenac, while time was more influential for salicylic acid; gels exhibited curvature, indicating diminishing returns at high rpm. Model-predicted optima were implementable on the Unguator™ with minor rounding of rpm/time. Cleaning validation confirmed post-sanitization residues below LOQ and <10 ppm acceptance. Conclusions: The Unguator™ provides a practical, parameter-controlled route for compounding pharmacies to standardize semisolid preparations, achieving reproducible layer-to-layer content uniformity within predefined criteria under the evaluated conditions through programmable set-points and validated cycles. DOE-derived rpm-time relationships define an operational design space within the studied ranges and support selection of implementable device settings and set-points. Importantly, the DOE-derived "optima" in this study are optimized for assay-based content uniformity (mean % label claim and strata variability). Cleaning validation supports a closed, low-cross-contamination workflow, facilitating consistent routines for both routine and complex formulations. Overall, the work implements selected QbD elements (QTPP-Quality Target Product Profile; CQA-Critical Quality Attribute definition; CPP-Critical Process Parameter identification; operational design space; and a proposed control strategy) and should be viewed as a step toward broader lifecycle QbD implementation in compounding.
More Related Videos
13:17Manufacture of Concentrated, Lipid-based Oxygen Microbubble Emulsions by High Shear Homogenization and Serial Concentration
Published on: May 26, 2014
10:12Flash NanoPrecipitation for the Encapsulation of Hydrophobic and Hydrophilic Compounds in Polymeric Nanoparticles
Published on: January 7, 2019
Related Concept Videos
In Vitro Drug Dissolution: Compendial Testing Models I
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Factors Influencing Drug Absorption: Pharmaceutical Parameters
In Vitro Drug Dissolution: Compendial Testing Models II
Mixing Concrete