Related Experiment Video
Updated: Feb 28, 2026

Measurements of CO2 Fluxes at Non-Ideal Eddy Covariance Sites
Published on: June 24, 2019
Low-Cost CO2 Sensors: On-Site Performance Evaluation and Co-Location Correction Procedure for Reliable Ventilation
David Honan1,2, John Garvey3, John Littlewood4
1Department of Civil, Structural & Environmental Engineering, Trinity College Dublin, The University of Dublin, D02 PN40 Dublin, Ireland.
Abstract:
Adequate ventilation is essential for maintaining indoor environmental quality in schools, where ventilation standards are often based on an indoor concentration of human-generated carbon dioxide (CO2) above ambient levels. Low-cost non-dispersive infrared (NDIR) CO2 sensors offer a practical solution for ventilation monitoring, yet variability between sensors can compromise accuracy, particularly when applications depend on the determination of precise concentration differences. This study evaluates the performance of twenty-three low-cost CO2 sensors, developing normalisation functions to improve comparability across sensors, introducing an accessible methodology for on-site sensor calibration without the need for laboratory-grade reference equipment. The sensors were co-located for three independent test periods in 2025 representing typical school internal conditions in Ireland. Pre-normalisation analysis showed strong linearity (coefficient of determination (R2) = 0.999) but notable variability, with a mean root mean square error (RMSE) of 18.3 ppm and 0.45% of measurements outside manufacturers stated accuracy. Normalisation models were trained and validated using a leave-one-period-out approach. Regression-based correction yielded the greatest improvement, reducing RMSE by 16%. When applied to the full dataset, final correction factors reduced RMSE by 27%, out-of-range measurements by 43%, and proportional bias by 31%. Corrected sensors demonstrated highly consistent performance, particularly within the CO2 ranges most relevant for classroom ventilation assessment, with an RMSE = 7.4 parts per million (ppm) at ambient concentrations and 11.9 ppm at concentrations below 1500 ppm. Field-based co-location in the deployment environment across full CO2 cycles, combined with a network-derived global reference, produced effective correction factors. Performance declined marginally above 1500 ppm and during dynamic occupancy, while overall accuracy remained strong. The study presents a practical and accessible methodology for evaluating and normalising low-cost CO2 sensors without specialised laboratory equipment, supporting reliable ventilation assessments in schools.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Measurement of Air Content in Concrete
The pressure method,...

