Related Experiment Video
Updated: Jun 20, 2026

09:54
A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Detection of apnea and hypopnea events using a wireless Abdomen-Worn sensor with SpO₂ integration
Thi Hang Dang1,2, Hyung-Ki Min2, Nam-Hwan Sung2
1Department of Electrical Engineering, Ulsan National Institute of Science and Technology, Ulsan, 44919, South Korea.
Sleep & Breathing = Schlaf & Atmung
|March 3, 2026
Abstract
No abstract available in PubMed .
Related Concept Videos
Pulse rhythm
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hyperpnea and Hyperventilation
Hyperventilation refers to a higher-than-normal rate and depth of breathing, often associated with anxiety attacks. This excessive breathing surpasses the body's need to expel CO2, leading to a condition known as hypocapnia - an unusually low level of carbon dioxide in the blood. Hypocapnia can constrict cerebral blood vessels, reducing blood flow to the brain, which may result in dizziness or fainting. Early signs include tingling and muscle spasms in the hands and face, caused by falling...
Pulse Oximetry
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Sleep Apnea
Sleep apnea is a condition where breathing stops intermittently during sleep, often leading to significant health issues. Each episode can last from 10 to 20 seconds or more and is frequently accompanied by a brief arousal from sleep. This disturbance, largely unnoticed by the individual, can lead to severe daytime fatigue. Commonly, individuals seek help after being informed by their partners about loud snoring and noticeable breathing pauses during sleep.
The condition is more prevalent among...
The condition is more prevalent among...
Holter Monitor: 24-Hour Monitoring
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...