Related Experiment Video
Updated: May 7, 2026

A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
Published on: September 16, 2017
CTP-Free Method for Automated Lesion Water Uptake in Acute Ischemic Stroke.
Laura M van Poppel1,2, Lucas de Vries3,2,4, Mahsa Mojtahedi3,2
1From the Department of Biomedical Engineering and Physics (L.M.v.P., L.d.V., M.M., H.A.M.), Amsterdam UMC, University of Amsterdam, the Netherlands l.m.vanpoppel@amsterdamumc.nl.
An automated method using CT angiography (CTA) and non-contrast CT (NCCT) accurately measures net water uptake (NWU) in ischemic stroke patients. This approach shows good agreement with traditional CT perfusion (CTP) methods and aids in identifying early treatment windows.
Area of Science:
- Neuroimaging
- Radiology
- Stroke Imaging
Background:
- Net water uptake (NWU) in ischemic stroke correlates with outcomes and lesion age.
- Traditional NWU measurement relies on CT perfusion (CTP), limiting its clinical use.
- Developing an automated NWU method using NCCT and CTA is crucial for wider applicability.
Purpose of the Study:
- To develop and validate an automated method for measuring NWU using only NCCT and CTA.
- To compare the performance of the automated CTA-NCCT approach with the traditional CTP-NCCT method.
Main Methods:
- Deep learning was used to automatically segment infarct core and hypoperfused areas from NCCT and CTA images in 90 stroke patients.
- NWU was calculated as the density difference between affected and contralateral regions.
- Agreement (ICC, Bland-Altman) and accuracy (ROC analysis) were assessed against CTP-NCCT-based NWU.
Main Results:
- The automated CTA-NCCT approach showed good agreement with CTP-NCCT for core NWU (ICC 0.81) and excellent agreement for hypoperfused area NWU (ICC 0.93).
- Both methods accurately identified patients within 4.5 hours of stroke onset based on core NWU (AUC 0.87).
- Hypoperfused area NWU did not significantly differentiate early vs. late treatment windows with either method.
Conclusions:
- Automated NWU measurement using CTA and NCCT is a viable alternative to CTP.
- This method demonstrates good agreement and comparable accuracy to traditional approaches.
- External validation is recommended to confirm the generalizability of these findings.
More Related Videos
06:45Author Spotlight: Integrated Photoacoustic, Ultrasound, and Angiographic Tomography (PAUSAT) for NonInvasive Whole-Brain Imaging of Ischemic Stroke
Published on: June 2, 2023
05:32Author Spotlight: Assessing Ischemic Stroke Damage Through Middle Cerebral Artery Occlusion Model
Published on: August 11, 2023
Related Concept Videos
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Imaging Studies for Cardiovascular System V: CT
Continuous Renal Replacement Therapy