Related Experiment Video
Updated: Mar 11, 2026

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Investigation of finite element simulation-based bond-slip effect for seismically vulnerable school reinforced
Haewon Kang1, Kihak Lee2, Suenghun Shin3
1Department of Architectural Engineering, Gyeongsang National University (GNU), Jinju- daero, Jinju-Si, 52828, Gyeongsangnam-do, South Korea.
Abstract:
Recent earthquakes have induced significant damage on reinforced concrete (RC) school buildings due to seismically deficient details, which can cause bonding failure between steel reinforcements and surrounding concrete due to low confinements. To mitigate the failure mechanism, a proper modeling method to capture the bond-slip effects is needed. This study aims to investigate hysteresis behavior of finite element (FE) models with three bonding modeling approaches (perfect, linear-elastic and nonlinear-inelastic bonding models) for a seismically vulnerable RC school building frame. The models were developed through three-step processes: (1) column model; (2) beam-column joint model; and (3) frame model. To quantify the simulation variation of bond-slip effects for key parameters of hysteresis curves (effective stiffness, maximum strength, and energy dissipation), the simulated responses were compared to the experimental results measured from quasi-static cyclic loading tests in each modeling process. While the perfect bonding model used by structural engineers overestimated all key parameters (e.g., 53.7% in energy dissipation) of the hysteresis curves, the nonlinear-inelastic bonding models reproduced the most accurate hysteresis behavior (less than 5.0%). Based on this investigation, uses of improper bonding models can exaggerate the seismic performance of the seismically vulnerable RC frames.
More Related Videos
Related Concept Videos
Indeterminate Structure
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Effects of Creep
Design Example: Distributing Reinforcements in Concrete Sections
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...

