Suspended Lead Suits and Radiation Exposure in Interventional Echocardiographers
David A McNamara1, Jeffrey M Decker1, Michael W McNamara1
1Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan.
Suspended lead suits significantly reduce occupational radiation exposure for interventional echocardiographers during left atrial appendage occlusion (LAAO) procedures compared to traditional lead aprons.
Area of Science:
- Cardiology
- Medical Imaging
- Occupational Health
Background:
- Percutaneous left atrial appendage occlusion (LAAO) procedures pose occupational radiation exposure risks to interventional echocardiographers (IEs).
- Optimal radiation shielding methods for IEs during LAAO are not well-established.
- IEs work in close proximity to radiation sources, increasing exposure risks.
Purpose of the Study:
- To compare the effectiveness of suspended lead suits versus traditional lead aprons in reducing IE radiation dose.
- To assess radiation dose reduction during LAAO procedures using different shielding methods.
Main Methods:
- A blinded, cross-sectional study involving 125 adult patients undergoing LAAO.
- IEs wore head-level dosimeters during procedures.
- Radiation doses were compared between IEs using suspended lead suits (95 cases) and traditional lead aprons (30 historical cases).
Main Results:
- Suspended lead suits resulted in a median radiation dose of 0.0 μSv, significantly lower than the 10.6 μSv with traditional lead aprons (P < .001).
- Radiation doses were undetectable in 60% of cases using suspended lead suits versus 0% with traditional aprons.
- No cases with suspended lead suits exceeded 20 μSv, compared to 30% of cases with traditional aprons.
Conclusions:
- Suspended lead suits significantly reduce head-level radiation dose for IEs during LAAO.
- These findings highlight the potential of suspended lead suits as an effective radiation shielding mechanism.
- Implementing suspended lead suits can mitigate occupational radiation exposure risks for IEs in structural heart interventions.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Holter Monitor: 24-Hour Monitoring
Cardiac Catheterization I: Pre-Procedure Overview