Quantitative Office-Based Laryngoscopy: Bench Validation of a Simple Calibration Method for Submillimeter Accuracy
Fabian Burk1, Gerhard Förster1, Robert Brunner2
1Department of Otorhinolaryngology, Plastic Surgery, SRH Wald-Klinikum Gera, Gera, Germany.
Journal of Voice : Official Journal of the Voice Foundation
|March 12, 2026
Summary
A new calibration method enables precise, submillimeter distance measurements using a CE-marked stereo laryngoscope. This approach is suitable for clinical and research use in transoral laryngoscopy without custom hardware.
Area of Science:
- Medical Imaging
- Otolaryngology
- Optical Engineering
Background:
- Quantitative laryngoscopy has been limited by the need for non-medical research prototypes.
- Commercial availability of medical devices is crucial for routine diagnostics and large-scale studies.
Purpose of the Study:
- To present and validate a simple, one-shot reference-grid calibration method for a CE-marked stereo laryngoscope.
- To enable quantitative laryngoscopic data acquisition in routine clinical settings.
Main Methods:
- Utilized a CE-marked 3D stereo laryngoscope to measure target distances at various working distances.
- Employed a reference-grid image to establish a px/mm scale for each frame.
- Assessed precision using standard deviation and accuracy via Bland-Altman analysis.
Main Results:
- Achieved a measurement precision with a standard deviation of 1.0%.
- Demonstrated high accuracy with a small bias of -0.3% and narrow limits of agreement (-2.2% to +1.6%).
- Measurement performance was consistent across different target and working distances without significant distortion.
Conclusions:
- The proposed calibration method is effective for a commercially available stereo endoscope.
- Provides precise, submillimeter distance measurements suitable for clinical and scientific applications.
- Facilitates office-based transoral laryngoscopy without requiring custom hardware.
More Related Videos
Related Concept Videos
Instrument Calibration
1.0K
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
1.0K
Glassware Calibration
1.7K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.7K
Calibration Curves: Linear Least Squares
4.9K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
4.9K