Related Experiment Video
Updated: Mar 14, 2026

07:09
Preparation and Application of a New Bacterial Biosensor for the Presumptive Detection of Gunshot Residue
Published on: May 9, 2019
8.5K
Objective evaluation of consecutively manufactured Glock Marksman Barrels using EvoFinder®
Jack McKeon1, Erich Smith1, Rachael Gominsky1
1FBI Laboratory, Firearms/Toolmarks Unit, Quantico, Virginia, USA.
Journal of Forensic Sciences
|March 13, 2026
Summary
Glock Marksman Barrels (GMBs) feature a new rail component. This study found that subclass carryover on GMB rails does not cause false positives in firearm identification, ensuring reliable toolmark analysis.
Area of Science:
- Forensic Science
- Firearm Examination
- Manufacturing Processes
Background:
- Glock Marksman Barrels (GMBs) incorporate an additional rail component into their polygonal rifling.
- This innovation has sparked debate among firearm examiners regarding its impact on identification accuracy.
Purpose of the Study:
- To investigate the manufacturing of GMBs, specifically focusing on subclass characteristics and striation variations.
- To determine if the added rail component aids or hinders microscopic comparisons by firearm examiners.
Main Methods:
- Information on GMB manufacturing was gathered from Glock engineers.
- Microscopic evaluation of casts from consecutively manufactured GMBs identified repeating patterns due to subclass carryover.
- Toolmarked surfaces of bullets fired from 10 consecutively manufactured GMBs were scanned into the EvoFinder® system for objective analysis.
Main Results:
- Repeating patterns were observed on GMB rails, attributed to mandrel manufacturing and subclass carryover.
- Objective evaluation using the EvoFinder® system demonstrated that subclass carryover did not impede bullet-to-barrel assignments.
- Inclusion of N-max criterion in scoring enabled complete separation of distributions, confirming reliable identification.
Conclusions:
- Subclass carryover on GMB rails does not lead to false positives in firearm identification.
- The additional rail component does not hinder, and may potentially aid, examiners in microscopic comparisons.
- The study validates the reliability of GMBs for forensic firearm examination.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
736
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
736
Fineness Modulus
1.7K
The fineness modulus (FM) of aggregate is a numerical index that measures the coarseness or fineness of the particles. It is calculated by adding the cumulative percentages of aggregate retained on each of a specified series of sieves and dividing the sum by 100.
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
1.7K

