Related Experiment Video
Updated: Mar 14, 2026

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
Nonprewhitening model observers in the Fourier and spatial domain: a comparison of predictions for iterative and deep
Gavin Poludniowski1,2, Rebecca Titternes1,2, Jessica Flores1,3
1Department of Nuclear Medicine and Medical Physics, Karolinska University Hospital, Framstegsgatan 23, D1:00, 17164 Stockholm, Sweden.
Abstract:
The nonprewhitening matched filter (NPWMF) is frequently used to assess task-based image quality in computed tomography (CT). However, modern reconstruction algorithms, based on iterative reconstruction (IR) or Deep Learning image reconstruction (DLIR), exhibit properties that undermine Fourier domain approaches. One alternative is to abandon the NPWMF. Here, instead, calculation of the NPWMF in the spatial domain is explored with and without assumption of Gaussian observer response. Model observer predictions of area-under-the-curve were determined for a Revolution CT scanner (GE Healthcare) and a NAEOTOM Alpha scanner (Siemens Healthineers). For the former, the vendor's IR and DLIR were investigated. For the latter, the vendor's IR was used and compared to results from a reader study. Results support the conclusion that Fourier domain calculations can exaggerate benefits of denoising and that spatial domain calculations can provide good agreement with human observers. Assumption of Gaussian observer response did not lead to substantial errors.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...