Robotic Myomectomy Using Hugo RAS Platform: a Step-by-Step on how to be Safe and Efficient.

Giovanna Moreira Arcas1, Carina Pita Lottenberg1, Debora Davalos Albuquerque Maranhao1

  • 1Department of Gynecology and Obstetrics, Einstein Hospital Israelita, São Paulo, Brazil (all doctors).

Journal of Minimally Invasive Gynecology
|March 13, 2026
PubMed
Summary

This study presents a safe robotic myomectomy using the Hugo™ RAS system for fertility preservation. The approach focused on cosmetic trocar placement and effective hemostasis, demonstrating feasibility in a selected case.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Knowledge of gynecologists in the public health system care of women victims of violence.

Revista da Associacao Medica Brasileira (1992)·2022
Same author

Metabolomic Profiling of Peripheral Plasma by GC-MS and Correlation With Size of Uterine Leiomyomas.

Journal of the Endocrine Society·2022
Same author

Laparoscopic approach to paravaginal low-grade sarcoma.

International journal of gynecological cancer : official journal of the International Gynecological Cancer Society·2021
Same author

Tricky Diagnosis and Robot-laparoscopic Surgical Approach to Disseminated Peritoneal Leiomyomatosis.

Journal of minimally invasive gynecology·2021
Same author

Evaluation of a Laparoscopic Multi-approach Training for Obstetrics and Gynecology Residents.

Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia·2020
Same author

Initial experience with single-port robotic hysterectomy.

Einstein (Sao Paulo, Brazil)·2018
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Area of Science:

  • Minimally Invasive Gynecologic Surgery
  • Robotic Surgery
  • Urogynecology

Background:

  • Uterine fibroids significantly impact women's reproductive health, causing abnormal bleeding and infertility.
  • Fertility-preserving myomectomy is crucial for women desiring future pregnancies.
  • Robotic-assisted surgery offers potential advantages in precision and control for complex gynecologic procedures.

Purpose of the Study:

  • To detail a safe and efficient robotic myomectomy technique using the Hugo™ RAS system.
  • To highlight aesthetic trocar placement and hemostatic strategies for uterine reconstruction.
  • To evaluate the feasibility of this approach in a fertility-preserving context.

Main Methods:

  • A case report of a 41-year-old nulliparous woman with symptomatic fibroids undergoing robotic myomectomy.

More Related Videos

Author Spotlight: Cutting-Edge Robotic Heller Myotomy Protocol for Treatment of Achalasia
09:46

Author Spotlight: Cutting-Edge Robotic Heller Myotomy Protocol for Treatment of Achalasia

Published on: February 16, 2024

1.6K
Robotic Myotomy and Partial Fundoplication for Achalasia
11:19

Robotic Myotomy and Partial Fundoplication for Achalasia

Published on: August 11, 2023

2.1K

Related Experiment Videos

Last Updated: Mar 15, 2026

Robotics in Surgery: A Modular Robotic Platform Driven Gastric Wedge Resection
07:27

Robotics in Surgery: A Modular Robotic Platform Driven Gastric Wedge Resection

Published on: February 7, 2025

1.3K
Author Spotlight: Cutting-Edge Robotic Heller Myotomy Protocol for Treatment of Achalasia
09:46

Author Spotlight: Cutting-Edge Robotic Heller Myotomy Protocol for Treatment of Achalasia

Published on: February 16, 2024

1.6K
Robotic Myotomy and Partial Fundoplication for Achalasia
11:19

Robotic Myotomy and Partial Fundoplication for Achalasia

Published on: August 11, 2023

2.1K
  • Utilized the Hugo™ RAS system with standard laparoscopic trocars and low abdominal port placement for cosmetic benefit.
  • Employed bilateral uterine artery clipping, intramyometrial vasopressin, and transvaginal specimen extraction for hemostasis and safety.
  • Main Results:

    • The robotic myomectomy was completed in 122 minutes with an estimated blood loss of 50 mL.
    • No intraoperative or postoperative complications were reported.
    • The procedure demonstrated feasibility and safety in this specific patient case.

    Conclusions:

    • Robotic myomectomy with the Hugo™ RAS system is a feasible and safe option for selected patients requiring fertility preservation.
    • The described technique emphasizes cosmetic outcomes and effective hemostasis.
    • Further comparative studies are needed to establish superiority over other robotic systems.