Related Experiment Video
Updated: Mar 19, 2026

08:21
Wideband Optical Detector of Ultrasound for Medical Imaging Applications
Published on: May 11, 2014
11.8K
Compact multi-period offset-spliced SMO-LPFG for ultralow-crosstalk dual-parameter sensing
Optics Express
|March 18, 2026
Summary
A novel fiber optic sensor minimizes temperature effects on refractive index measurements. This compact device offers high accuracy for multiparameter sensing applications.
Area of Science:
- Photonics and Optical Sensing
- Fiber Optic Sensors
- Biomedical and Chemical Sensing
Background:
- Temperature fluctuations cause spectral drift, limiting the precision of surrounding refractive index (SRI) sensors.
- Accurate SRI measurements are crucial for various applications, including environmental monitoring and medical diagnostics.
Purpose of the Study:
- To propose and demonstrate a compact single-mode-multimode offset-spliced long-period fiber grating (SMO-LPFG) sensor.
- To achieve high sensitivity and low temperature crosstalk for accurate SRI sensing.
- To enable simultaneous decoupling of SRI and temperature for multiparameter measurements.
Main Methods:
- Fabrication of a compact SMO-LPFG using three periods of SMF-MMF offset splicing (20µm lateral offset, 2.4mm device length).
- Analysis using beam-propagation simulations and experimental validation.
- Application of a sensitivity matrix approach for data analysis.
Main Results:
- The SMO-LPFG sensor demonstrated SRI sensitivities of 14.5 nm/RIU and 217.88 nm/RIU.
- A temperature sensitivity of 105 pm/°C was recorded.
- An ultralow temperature crosstalk of 2.04 × 10-5 RIU/°C was achieved.
Conclusions:
- The developed SMO-LPFG sensor effectively mitigates temperature-induced spectral drift.
- The sensor's high sensitivity, low crosstalk, and ability for simultaneous SRI and temperature decoupling make it suitable for high-precision sensing.
- The simple fabrication and compact design enhance its attractiveness for practical multiparameter sensing applications.
Related Concept Videos
Cascaded Op Amps
1.2K
Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
1.2K
Double Resonance Techniques: Overview
833
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
833