Related Experiment Video
Updated: Mar 19, 2026

06:51
Measuring the Complete-arch Distortion of an Optical Dental Impression
Published on: May 30, 2019
8.1K
Evaluation of Dimensional Changes in Stone Casts from Disinfected Elastomeric Impressions Using Coordinate Measuring
Chaitra S Bulla1, Shivakumar N Puranik1, Santosh Kumar Bung1
1Department of Prosthodontics, HKE'S S. Nijalingappa Institute of Dental Sciences and Research Kalaburagi, Karnataka, India.
Journal of Pharmacy & Bioallied Sciences
|March 18, 2026
Summary
Disinfection of dental impression materials does not harm dimensional accuracy. Addition Silicone with 2% Glutaraldehyde offers the best results for prosthodontic models, ensuring precision in dental restorations.
Area of Science:
- Dental Materials Science
- Prosthodontics
- Infection Control
Background:
- Effective disinfection of elastomeric impression materials is crucial in prosthodontics to prevent cross-contamination.
- Maintaining dimensional accuracy of impressions after disinfection is vital for precise dental restorations.
Purpose of the Study:
- To evaluate the three-dimensional changes in die stone models made from three different elastomeric impression materials after disinfection.
- To compare the dimensional stability of Addition Silicone, Condensation Silicone, and Polyether after treatment with three common disinfectants.
Main Methods:
- 120 impressions were made using Addition Silicone, Condensation Silicone, and Polyether.
- Impressions were disinfected with 5.25% Sodium Hypochlorite, 2% Glutaraldehyde, or 2% Chlorhexidine for 10 minutes.
- Die stone models were poured and measured using a coordinate measuring machine (CMM) to assess dimensional changes.
Main Results:
- Addition Silicone exhibited the highest dimensional accuracy across all tested disinfectants.
- 2% Glutaraldehyde demonstrated superior preservation of dimensional fidelity compared to Sodium Hypochlorite and Chlorhexidine.
- Polyether showed the most significant dimensional variation, particularly in the control group.
Conclusions:
- Disinfection protocols do not adversely affect the dimensional stability of elastomeric impression materials.
- The combination of Addition Silicone and 2% Glutaraldehyde is recommended for optimal dimensional accuracy in prosthodontic applications.
- The hydrophilic nature of Polyether may contribute to its reduced dimensional stability post-disinfection.