Related Experiment Video
Updated: Mar 19, 2026

Multimodality Diagnosis of Mesenteric Ischemia
Published on: July 21, 2023
Serial false lumen patency evaluation of a type B dissection represented with malperfusion following medical
S Taha Zaidi1, Quang Le1, Firas Mussa1
1Division of Vascular Surgery, Department of Cardiothoracic and Vascular Surgery, McGovern Medical School at The University of Texas Health Science Center at Houston, Houston, TX.
Abstract:
False lumen evolution in type B aortic dissection, particularly with medical management and anticoagulation, remains incompletely understood. We report a 55-year-old man on apixaban for pulmonary embolism with a subacute zone 3-10L TBAD without malperfusion. He was managed medically initially and represented twice over 2 months with back pain and acute right lower extremity ischemia. Serial imaging demonstrated dynamic remodeling with progression from partial to near-complete thrombosis to full reperfusion with true lumen compression. Urgent endovascular repair was performed successfully. This case illustrates the unpredictable course of medically managed TBAD and need for judicious use of anticoagulation.
Related Concept Videos
Aortic Regurgitation IV: Nursing Management
Aneurysm IV: Nursing Management
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Aneurysm III: Interprofessional Care