Comparison of PEEP titration methods to improve respiratory system compliance in acute respiratory distress syndrome:
Israel Silva Maia1, Mariangela Pimentel Pincelli1, Cassio Luis Zandonai1
1Hospital Nereu Ramos - Florianópolis (SC), Brazil.
Objective:
To compare the effects of four positive end-expiratory pressure titration methods on respiratory system compliance over the first 3 days of mechanical ventilation and to analyze the agreement between derived positive end-expiratory pressure and compliance values among these methods immediately after randomization.
Methods:
Single-center, randomized study acute respiratory distress syndrome patients were assigned to one of four groups based on positive end-expiratory pressure titration methods: electrical impedance tomography, transpulmonary pressure measured via an esophageal catheter, the best compliance approach with daily positive end-expiratory pressure titration, and a control group using a low positive end-expiratory pressure/ fraction of inspired oxygen table with adjustments as necessary. The primary outcome was mean respiratory system compliance over the first 3 days of mechanical ventilation. Immediately post-randomization, the best positive end-expiratory pressure according to each method was assessed for every patient, and within-patient agreement of titrated positive end-expiratory pressure and compliance for pairs of methods was calculated with the Bland-Altman method.
Results:
Forty-nine patients participated. Compared to control, the mean difference in compliance was 0.03mL/cmH2O (95%CI -2.74 to 2.8) in the Electrical impedance tomography Group; 1.90mL/cmH2O (95%CI -0.98 to 4.78) in the Catheter Group, and 1.42mL/cmH2O (95%CI -1.35 to 4.19) in the best compliance group. Within-patient agreement of titrated positive end-expiratory pressure and compliance was poor, with 95% limits of agreement ranging from -9.3 to 9cmH2O for positive end-expiratory pressure and from -8.5 to 11.4mL/cmH2O for compliance.
Conclusion:
No significant differences in mean respiratory system compliance were found among positive end-expiratory pressure titration methods compared to control. The agreement between titrated positive end-expiratory pressure and respiratory system compliance using different methods was low.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Acute Respiratory Failure-IV
Acute Respiratory Failure-III