Multi-objective optimization of mechanical properties of braided stents based on an improved response surface model
Rongye Zheng1,2, Chen Zhang1, Chengtao Zhu1
1School of Mechanical Engineering and Automation, Fuzhou University, Fuzhou, China.
None:
Although braided stents are widely adopted for intracranial aneurysm treatment, current designs still struggle with simultaneously satisfying the conflicting demands of mechanical properties including radial pressure, bending moment and foreshortening. This study proposed a multi-objective optimization framework based on an improved response surface model (IRSM) for the personalized design of braided stents, to enhance their adaptability to specific lesions. The IRSM was constructed for the aforementioned mechanical properties and integrated with design of experiments to accurately characterize intrinsic relationships between design parameters and mechanical properties. Based on 45 training samples, the IRSM demonstrated high accuracy in modeling the intrinsic relationships between design parameters and mechanical properties. Assessed using leave-one-out cross-validation, it achieved a coefficient of determination R2 > 0.9580 and a mean squared error MSE < 0.0410. Then, multi-objective optimization was implemented to obtain the Pareto-optimal solutions by the non-dominated sorting genetic algorithm II. Finite element simulations were performed separately for both the commercial stent pipeline and the selected Pareto-optimal solution. The comparative results revealed that this selected Pareto-optimal solution effectively increases radial pressure and reduces foreshortening, while inevitably leading to an increase in bending moment, thereby highlighting the importance of conducting coordinated trade-offs and optimizations of multiple objectives based on specific clinical scenarios in personalized stent design.
More Related Videos
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
06:55Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
Related Concept Videos
Response Surface Methodology
The process of RSM involves several key steps:
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Methods of Medium Optimization
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Members Made of Elastoplastic Material
As the bending moment...