Related Experiment Video
Updated: Mar 24, 2026

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
ZS4D: Zero-Shot Self-Similarity-Steered Denoiser for Volumetric Photon-Counting CT
Yongyi Shi1, Chuang Niu1, Wenjun Xia1
1Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 USA.
Abstract:
Photon-counting computed tomography (PCCT) has emerged as a transformative imaging modality, enabling enhanced spatial resolution, and multi-energy acquisition with energy-discriminating detectors of significantly smaller detector elements. However, both energy discriminating power and reduced detector pixel size result in fewer detected photons per measurement, inherently increasing noise in reconstructed images. In this study, we propose ZS4D, a zero-shot self-similarity-steered denoiser for PCCT reconstruction. Specifically, a self-similarity denoiser is pre-trained in a self-supervised manner by leveraging spectral correlations through multi-energy extraction and capturing volumetric context via the complementary synergy of axial and sagittal planes. The pre-trained denoiser is then integrated as a prior into an iterative reconstruction framework, enabling effective noise suppression and structural preservation. Extensive experiments demonstrate that ZS4D adapts well to varying noise levels and significantly enhances image quality in both simulated and pre-clinical PCCT datasets. Also, ZS4D demonstrates effectiveness in deblurring tasks. Furthermore, our denoiser pretrained on clinical PCCT data is shown to enhance the spatial resolution of conventional CT images.
More Related Videos
07:12Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
Published on: January 6, 2026
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...