Purpose:
Residual stresses are intrinsic stresses present in arteries even in the absence of external loads or blood pressure. They originate during growth and remodeling and contribute to vascular mechanical equilibrium. Despite advances in computational methods, incorporating residual stresses into patient-specific vascular models remains challenging. Evidence regarding the influence of circumferential residual stresses on physiological loading in realistic anatomies is still limited.
Methods:
We combined in vitro imaging, mechanical testing, and finite element (FE) simulations to incorporate residual stresses into a pressurized porcine aorta model. Medical images were acquired in both pressurized and zero-stress states, the latter obtained after 2 h of longitudinal cutting. Locally measured mechanical properties from distinct aortic regions were used to define an orthotropic hyperelastic material response. Residual stresses were restored by simulating vessel closure under displacement-controlled boundary conditions with a tied contact interface. Stress distributions were then compared in FE pressurization simulations performed with and without residual stresses.
Results:
Residual stresses substantially influenced the predicted stress fields. They homogenized stress across the vessel thickness and reduced stress concentrations near the lumen. Moreover, lumen cross-sectional areas at 120 mmHg aligned more closely with experimental measurements when residual stresses were included. In contrast, neglecting residual stresses produced an average overestimation of lumen area by 4.84% and stress peaks up to 50% higher in the inner wall.
Conclusion:
This study highlights the importance of accounting for residual stresses in biomechanical vascular simulations. Incorporating them improves prediction accuracy and reduces artificial stress concentrations, which is crucial for patient-specific risk assessment and surgical planning.
More Related Videos
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Residual Stresses
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Stress Concentrations
Stress Concentrations
The stress...
Residual Stresses in Circular Shafts
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....