Related Experiment Video
Updated: Mar 25, 2026

08:01
Fabrication of Zero Mode Waveguides for High Concentration Single Molecule Microscopy
Published on: May 12, 2020
8.8K
How to Manage the Humidity of Biological Samples to Reduce Interference on Chemical Sensors
Ana Maria Tischer1, Beatrice Julia Lotesoriere1, Laura Capelli1
1Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy.
Critical Reviews in Analytical Chemistry
|March 24, 2026
Summary
High humidity in biological gas samples interferes with chemical sensors used for clinical diagnosis. This review guides researchers on managing humidity using five sampling strategies for improved diagnostic accuracy.
Area of Science:
- Analytical Chemistry
- Sensor Technology
- Clinical Diagnostics
Background:
- High humidity in biological gas samples (e.g., exhaled breath) interferes with chemical sensors.
- This interference reduces sensitivity and stability, hindering clinical validation of sensor systems.
- Managing humidity is critical for accurate clinical diagnosis using chemical sensors.
Purpose of the Study:
- To provide a practical guide for managing humidity in biological gas samples for chemical sensor analysis.
- To analyze humidity interference mechanisms and discuss mitigation strategies.
- To critically review sampling techniques for their application in chemical sensor analysis for clinical diagnosis.
Main Methods:
- Analysis of humidity interference mechanisms in chemical sensors.
- Review of established dehumidification strategies from analytical techniques.
- Critical evaluation of five sampling strategies: condensation, permeation, desiccants, dry dilution, and water traps.
- Discussion of operating principles, applications, advantages, limitations, and contamination risks for each method.
Main Results:
- Humidity interference significantly impacts the performance of chemical sensors for biological gas analysis.
- Five distinct sampling strategies (condensation, permeation, desiccants, dry dilution, water trap) were reviewed for humidity management.
- Each strategy presents trade-offs between residual humidity and analyte recovery, necessitating careful selection based on the specific application.
Conclusions:
- Effective humidity management is essential for the reliable clinical application of chemical sensors.
- Implementing appropriate sampling strategies can transform humidity from a confounder into a controlled variable.
- Thoughtful application of these strategies enables safer and more accurate measurements for clinical diagnosis.
Related Concept Videos
Sample Handling
2.9K
Transportation of samples from the collection point to the laboratory, as well as storage and preservation techniques, are crucial for maintaining sample integrity and ensuring accurate and reliable test results.
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
2.9K
Preparation of Samples for Electron Microscopy
7.7K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
7.7K
Atomic Absorption Spectroscopy: Interference
2.3K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.3K