Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Investigation of a Novel Snout-Mounted Quad-Compton Camera system for In Vivo Proton Dose Verification via Prompt
Vijay R Sharma1,2, E Shakeri3, Z Jiang4
1Department of Radiation Oncology, School of Medicine, University of Maryland, Baltimore, MD, USA.
None:
This study presents a novel simulation study for integrating four Compton Cameras (CC) into proton therapy systems by mounting them directly on the snout of the treatment gantry for prompt gamma imaging (PGI). This compact, fixed geometry simplifies detector integration, maintains alignment with the proton beam axis, and supports in vivo proton range verification. A Geant4-based Monte Carlo framework, PJ-MC, was used to simulate prompt gamma emissions (PGE) in water and patient-specific geometry. PG image reconstruction was performed using the Kernel Weighted Back Projection (KWBP) algorithm. To improve range accuracy, we introduced a post-processing method called Point Source Normalization (PSN), which uses precomputed PGI responses for monoenergetic gamma point sources at different depths to normalize PGI images and correct distortions from attenuation, geometric factors, and detector responses from PGE detected curve. Simulations with monoenergetic sources confirmed the influence of depth-dependent attenuation and inverse square losses, especially at higher proton energies. Clinical beam energies of 70, 150, and 200 MeV were tested. KWBP reconstructions showed increasing range discrepancies with energy, reaching 176 mm (water) and 144 mm (patient) at 200 MeV. PSN correction reduced these errors by up to 70%, bringing PG hotspots closer to the Bragg peak . Simulations with anterior/posterior shifts showed that the PSN-corrected system could detect millimeter-scale range deviations from setup uncertainties and beam shifts. This is the first study to simulate and evaluate a snout-mounted CC system for PGI in proton therapy. Results support future validation under clinical beam conditions in phantoms and patients.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...