Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

10.3K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
10.3K
Network Function of a Circuit01:25

Network Function of a Circuit

995
Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
995
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

1.1K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Frequency Response of a Circuit01:20

Frequency Response of a Circuit

934
Inductive circuits present intriguing challenges in electrical engineering, particularly during the transition from the time domain to the frequency domain. This transformation involves converting inductors into impedances and utilizing phasor representation.
The transfer function is pivotal in characterizing how these circuits react to various frequencies, facilitating a profound understanding of their behavior. An essential parameter is the time constant, signifying the...
934
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

1.4K
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.4K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

2.0K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
2.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Metastasectomy versus stereotactic body radiotherapy for lung metastases: a systematic review and meta-analysis of reconstructed time-to-event data on overall and progression-free survival.

Journal of thoracic disease·2026
Same author

Altered manganese and iron biomarkers in welders: a multi-element biomonitoring study across blood, serum and urine.

Frontiers in public health·2026
Same author

A vendor-neutral functional MRI acquisition protocol for multi-site studies.

Aperture neuro·2026
Same author

The Impact of Pre-Transplant Ventricular Assist Device Support on Survival After Heart Transplantation in Pediatric Patients: A Systematic Review and Meta-Analysis of Reconstructed Time-To-Event Data.

Pediatric transplantation·2026
Same author

Dynamic 3D MRI of vocal fold oscillations: In vivo assessment of vocal fold thickness, contact area, and glottal area waveform across phonation types in comparison with high-speed imaging.

The Journal of the Acoustical Society of America·2026
Same author

Phantom- and simulation-based validation of combined diffusion relaxometry in ex vivo ADRD white matter.

bioRxiv : the preprint server for biology·2026

Related Experiment Video

Updated: Mar 27, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

20.2K

Correction: Naming convention for gradient system transfer function and gradient system frequency response for

Niklas Wehkamp1, Patrick Hucker2, Johannes Fischer2

  • 1Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany. niklas.wehkamp@uniklinik-freiburg.de.

Magma (New York, N.Y.)
|March 26, 2026
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

10.0K
Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

10.1K

Related Experiment Videos

Last Updated: Mar 27, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

20.2K
Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
07:01

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples

Published on: June 9, 2016

10.0K
Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

10.1K