Related Experiment Video
Updated: Mar 29, 2026

Simple Methods for the Preparation of Non-noble Metal Bulk-electrodes for Electrocatalytic Applications
Published on: June 21, 2017
Development of a novel voltammetric method for revefenacin determination using modified electrodes in pharmaceutical
Sherin F Hammad1, Hala M Habib2, Hassan A Hendawy2
1Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Tanta University, Elgeish street, Tanta, Egypt. Sherinhammad@pharm.tanta.edu.eg.
Abstract:
Revefenacin (REV) is an inhalation solution used for management of Chronic Obstructive Pulmonary Disease (COPD) in the USA, this is single medication that is an approved bronchodilator delivered by nebulization with a once-daily frequency. Even though the crucial necessity of quality control in pharmaceutical manufacturing, no officially recognized methods exist for REV determination in biological samples. A sensitive, economical, simple and efficient electrochemical procedure using carbon paste modified with nanostructured zinc oxide electrode (ZnO-NPs/CPE) was designed for remarkably trace analysis of REV. It was demonstrated that the (ZnO-NPs/CPE) electrode in the Britton-Robinson buffer adjusted to pH 4.0 with the anionic surfactant sodium dodecyl sulfate (SDS), the electrochemical oxidation of REV was significantly enhanced. Under optimal conditions, the REV electrochemical process was irreversible and adsorption-mediated. Scanning Electron Microscopy (SEM) and Energy-Dispersive X-ray Spectroscopy (EDX) were utilized to characterize the morphology of the modified electrode. Under optimal experimental conditions, the analytical results showed direct relationship responses in the range of 0.19-2.0 µg mL-1 and a low limit of detection (LOD) of 0.04 µg mL-1 and limit of quantification (LOQ) of 0.13 µg mL-1. Our investigation reveals the outstanding applicability of the suggested sensor in quality control laboratories to achieve the fast determination for REV across various sample types (pure form, dosage form, biological samples).
Related Concept Videos
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Pulse Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Factors Affecting Measurements

