Related Experiment Video
Updated: Mar 29, 2026

Multi-Scale Modification of Metallic Implants With Pore Gradients, Polyelectrolytes and Their Indirect Monitoring In vivo
Published on: July 1, 2013
PLGA-Based In Situ-Forming Implants, a Quality by Design Perspective
Nayelli Campos-Morales1, Luz Graciela Cervantes-Pérez2, Alicia Sánchez-Mendoza2
1Ciencias Farmacéuticas, Universidad Autónoma Metropolitana, Unidad Xochimilco, Calzada del Hueso 1100, Colonia Villa Quietud, Alcaldía Coyoacán, Mexico City C.P. 04960, Mexico.
Abstract:
In situ-forming implants (ISFIs) based on poly(lactic-co-glycolic acid) (PLGA) offer a promising platform for long-acting parenteral drug delivery, enabling minimally invasive administration without surgical implantation. However, the development and clinical translation of PLGA-based ISFIs are hindered by formulation complexity, sensitivity to aterial variability, and limited predictability of drug release, particularly during early implant formation. Although previous reviews have described formulation components and release mechanisms, a comprehensive integration of Quality by Design (QbD) principles with a focus on risk prioritization remains absent. This review examines the application of QbD to solvent-exchange PLGA-based ISFIs, with an emphasis on identifying critical material attributes (CMAs) governing implant formation, burst release, and long-term release performance. Risk-based prioritization of CMAs and the role of design of experiments are systematically discussed. Special attention is given to burst release as a major CMA affecting safety, efficacy, and translational robustness. The evidence indicates that formulation-driven CMAs, such as polymer physicochemical properties, drug characteristics, and solvent selection, exert a greater influence on ISFI performance than process-related parameters. This review provides a structured perspective to support rational formulation design, improved reproducibility, and enhanced clinical translation of PLGA-based ISFI systems.