Related Experiment Video
Updated: Mar 31, 2026

Subsurface Defect Localization by Structured Heating Using Laser Projected Photothermal Thermography
Published on: May 15, 2017
Insulator string defect detection method for transmission lines based on image color analysis and multi-scale feature
Xinhai Chen1, Li Huang2, Jiewen Shen1
1College of Electrical Engineering & New Energy, China Three Gorges University, Yichang, 443002, China.
Abstract:
High-voltage overhead transmission line insulator strings are persistently exposed to harsh environments such as heavy rain, lightning, strong ultraviolet radiation, and significant temperature variations, which can readily lead to the deterioration of their electrical and mechanical performance. This degradation may result in defects like flashover and physical damage, posing a severe threat to grid security. To achieve efficient and accurate identification of defects in insulator strings, this paper proposes a detection method that integrates RGB color space analysis with multi-scale feature compensation. Firstly, preliminary segmentation of the insulator region is performed based on RGB component thresholds, and coarse localization of the insulator string is accomplished by combining morphological operations with non-overlapping window texture analysis. Subsequently, the minimum enclosing horizontal rectangle of the target is generated, enabling fine localization of the insulator string and segmentation of the horizontal rectangular region based on the texture features within the bounding box. Finally, a multi-scale compensation detection network is constructed, which employs multi-level detection heads to differentially compensate for missing high- and low-frequency information, thereby enhancing defect recognition accuracy. Experiments demonstrate that the proposed method significantly outperforms eight mainstream object detection models in terms of mean Average Precision (mAP). Through rigorous experimental validation, at an Intersection over Union (IoU) threshold of 0.5, the mAP of our method shows an improvement of approximately 4.1% points compared to the best-performing baseline method.
More Related Videos
11:14Comprehensive Characterization of Extended Defects in Semiconductor Materials by a Scanning Electron Microscope
Published on: May 28, 2016
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Lossy Lines and Overvoltages
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Transmission Line Design Considerations
Fault Types
For line-to-line faults occurring between phases B and C, the...
Lossless Lines
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Traveling Waves: Lossless Lines