Wearable sensing technology for knee joint monitoring and functional assessment: a systematic review
Abstract:
Traditional knee joint monitoring and assessment methods rely heavily on subjective evaluations, leading to an increasing interest in wearable sensing technology for objectively monitoring knee joint function. This review evaluates current research on wearable devices for knee monitoring and functional assessment, highlighting current approaches, limitations, technological advancements and identifying knowledge gaps to guide future research. Following PRISMA guidelines, a systematic search of PubMed, Scopus, IEEE Xplore, Web of Science, Cochrane Library, and Google Scholar identified 77 eligible studies, with methodological quality assessed using the COSMIN Risk of Bias tool. Findings were categorized into four domains: kinetics, kinematics, muscle activity, and integrated domains based on the measured biomechanical parameter. Knee angles were the most frequently measured parameter; however, significant methodological variability was identified, particularly inconsistent sensor placement protocols, calibration methods, and limited real-life applicability. The COSMIN assessment revealed few studies achieved high overall reliability ratings, with kinematics showing the highest consistency and muscle activity the lowest. Kinetic assessments primarily measured knee adduction moments with generally acceptable accuracy but were constrained by indirect measurement methods. Muscle activity assessments predominantly employed surface electromyography, yet exhibited substantial inconsistencies, particularly in electrode placement and analysis techniques. Integrated biomechanical assessments showed significant potential but were constrained by the lack of simultaneous multi-parameter measurement capabilities. Notably, ML/DL integration demonstrated promise, though inconsistencies in performance metrics and sensor configurations complicate direct comparisons, emphasizing the need for standardized evaluation criteria for broader clinical applicability.
More Related Videos
06:52An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
07:33In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023