Introduction:
Regular physical activity at a moderate-to-vigorous intensity is associated with a lower risk of recurrent cardiovascular events and mortality in individuals with coronary heart disease (CHD). Walking is a common form of physical activity; however, there is no evidence-based recommendation for the optimal step cadence (steps per minute) to achieve these intensity levels among individuals with coronary heart disease. Thus, this study aimed to establish the agreement between manually counted step cadence and step cadence assessed by waist- and wrist-worn accelerometers during treadmill walking among individuals with CHD. Next, the study aimed to establish the association between manually counted and accelerometer-assessed step cadence with cardiorespiratory intensity, followed by the development and validation of cadence thresholds for moderate- and vigorous-intensity levels.
Methods:
Participants (n = 87) performed a graded treadmill test. Step cadence was counted manually and by a waist- and wrist-worn accelerometer (Actigraph GT3x). Step cadence and oxygen consumption were measured during the final minute of walking at four speeds (3-6 km·h- 1). Agreement between manual and accelerometer cadence was established using Bland-Altman analyses. Step cadence thresholds for relative (%VO₂ peak) and absolute (METs) intensity were derived using generalized estimating equations in a training cohort (70%) and validated in a validation cohort (30%).
Results:
Accelerometers underestimated the aggregated cadence compared with manual assessments, with a mean difference of -16 and -31 steps/min for waist- and wrist-worn accelerometers, respectively, with a higher level of agreement at higher speeds. Manually assessed cadence thresholds for moderate intensity were 99 (relative) and 92 (absolute) steps/min compared with 61 and 45 steps/min from waist-worn accelerometers. For vigorous intensity, manual and accelerometer thresholds were similar: 116 vs. 112 (relative) and 126 vs. 135 (absolute) steps/min. Both methods effectively identified valid thresholds for moderate and vigorous cardiorespiratory intensity.
Conclusion:
Step cadence is a valid indicator of intensity in CHD populations, with manual and accelerometer methods showing comparable accuracy, despite accelerometer underestimation at lower speeds.
Clinical Trial Registration:
Australian New Zealand Clinical Trials Registry (ANZCTR): ACTRN12623000605695 (02062023).
More Related Videos
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
04:24A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Related Concept Videos
Coronary Artery Disease IV: Preventive Measures
Coronary Artery Disease I: Introduction
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Coronary Artery Disease II: Pathophysiology
Acute Coronary Syndrome I: Introduction
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...